2020
DOI: 10.2147/opth.s238841
|View full text |Cite
|
Sign up to set email alerts
|

<p>Refractive and Visual Outcomes After Bilateral Implantation of a Trifocal Intraocular Lens in a Large Population</p>

Abstract: Purpose: To review refractive, visual acuity, defocus curve and contrast sensitivity results after bilateral implantation of a trifocal intraocular lens (IOL) in a large population. Setting: One site in Santiago, Chile. Design: Single arm, non-randomized retrospective chart review. Methods: This was a single-arm retrospective chart review of clinical outcomes after bilateral implantation of a trifocal IOL (Panoptix ®), both toric and non-toric versions. Binocular visual acuity at 4 m, 60 cm and 40 cm was teste… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

10
37
2

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 23 publications
(49 citation statements)
references
References 16 publications
10
37
2
Order By: Relevance
“…Other causes for the differences observed in our study could be the length of follow-up and preoperative refraction. It is interesting to note that the results reported by Carreño et al 13 for percentage of eyes ≤0.25 D (66%) appear in between our results of BRA and PRA (45% and 90.5%, respectively). Mean postoperative cylinder after TTI with the Acrysof Panoptix IQ IOL has been reported previously between −0.21 and 0.28.…”
Section: Discussionsupporting
confidence: 70%
See 4 more Smart Citations
“…Other causes for the differences observed in our study could be the length of follow-up and preoperative refraction. It is interesting to note that the results reported by Carreño et al 13 for percentage of eyes ≤0.25 D (66%) appear in between our results of BRA and PRA (45% and 90.5%, respectively). Mean postoperative cylinder after TTI with the Acrysof Panoptix IQ IOL has been reported previously between −0.21 and 0.28.…”
Section: Discussionsupporting
confidence: 70%
“…Mean postoperative cylinder after TTI with the Acrysof Panoptix IQ IOL has been reported previously between −0.21 and 0.28. 13,14,20,21 Our results with IA 0.07 ± 0.19 D fall close to the middle of this range, while the results of our back-calculations using preoperative planned power, 0.31 ± 0.33 D fall outside it. Postoperative MRSE in our study (0.01 ± 0.27 D) fell close to the middle of the range for previously published results (−0.07-0.12 D) 14,20,21 of TTI with the Acrysof Panoptix IQ IOL.…”
Section: Discussionsupporting
confidence: 66%
See 3 more Smart Citations