1999
DOI: 10.1117/12.356823
|View full text |Cite
|
Sign up to set email alerts
|

<title>In-vivo evaluation of layered scattering coefficients and refractive indices with OCT</title>

Abstract: Besides morphological images created by optical coherence tomography (OCT), further parameters are evaluated in skin tissue under in vivo conditions. Scattering coefficients and refractive indices may support tissue characterization for research and diagnostic purposes in cosmetics I pharmacy and medicine, respectively. The known Klett algorithm'5 has been applied for retrieval of scattering coefficients. To permit refractive index evaluation, the sample arm of our OCT setup has been arranged to minimize mecha… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2004
2004
2016
2016

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 1 publication
0
2
0
Order By: Relevance
“…Apart from this, the use of a 40 × 0.6 NA objective in combination with a 25 µm pinhole will give more precise results than a 100 × 1.25 NA objective and 50 µm pinhole (lower mean coefficients of variation) and the use of a 100 × 1.25 NA objective and 50 µm pinhole might slightly overestimate the procaine amount in the upper few micrometers of the skin. The expectation that the 100 × 1.25 NA objective and 50 µm pinhole would give accurate results as it is an oil immersion objective with an immersion oil that refractive index is similar to the stratum corneums (immersion oil: 1.51, stratum corneum: 1.47) was therefore only partially met. Interestingly, the 40 × 0.6 NA objective in combination with the 25 µm pinhole was found to give accurate results with respect to similarity of the penetration profile to that of the cross sections.…”
Section: Resultsmentioning
confidence: 99%
“…Apart from this, the use of a 40 × 0.6 NA objective in combination with a 25 µm pinhole will give more precise results than a 100 × 1.25 NA objective and 50 µm pinhole (lower mean coefficients of variation) and the use of a 100 × 1.25 NA objective and 50 µm pinhole might slightly overestimate the procaine amount in the upper few micrometers of the skin. The expectation that the 100 × 1.25 NA objective and 50 µm pinhole would give accurate results as it is an oil immersion objective with an immersion oil that refractive index is similar to the stratum corneums (immersion oil: 1.51, stratum corneum: 1.47) was therefore only partially met. Interestingly, the 40 × 0.6 NA objective in combination with the 25 µm pinhole was found to give accurate results with respect to similarity of the penetration profile to that of the cross sections.…”
Section: Resultsmentioning
confidence: 99%
“…The behavior of the SC was interpreted by moisture uptake from sweating. 116,117 The effect of moisture uptake and sweating as a result of interaction of measuring probe with skin and their contributions to signal variations has not been estimated.…”
Section: Non-invasive Glucose Measurement 675mentioning
confidence: 99%