1972
DOI: 10.1016/0043-1648(72)90413-9
|View full text |Cite
|
Sign up to set email alerts
|

Lubrication of carbon fibre-reinforced polymers part I—Water and aqueous solutions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
68
0

Year Published

1997
1997
2017
2017

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 157 publications
(69 citation statements)
references
References 5 publications
1
68
0
Order By: Relevance
“…The results obtained in this work are in good agreement with results reported by Tanaka [25] and Lancaster [21]. The wear of carbon fibre-reinforced polymers in water, sea water, or aqueous solutions is generally greater than that obtained under dry wear test conditions.…”
Section: Effect Of Demineralized Water On Composite Plasticitysupporting
confidence: 82%
See 1 more Smart Citation
“…The results obtained in this work are in good agreement with results reported by Tanaka [25] and Lancaster [21]. The wear of carbon fibre-reinforced polymers in water, sea water, or aqueous solutions is generally greater than that obtained under dry wear test conditions.…”
Section: Effect Of Demineralized Water On Composite Plasticitysupporting
confidence: 82%
“…Lancaster reported that water and aqueous solution inhibit the formation of a transfer film on the counter body [21]. This film can be formed by the accumulation of epoxy debris [22] or by the accumulation of graphitic flakes originating from the carbon fibers [13].…”
Section: Coefficient Of Frictionmentioning
confidence: 99%
“…n to interfere with the transfer film formation of self-lubricating bearing materials [3,4]. When SustainaLube is used, the wear rates are too small to be determined within the test time of 10 h for all bearing materials except Thordon Thorplas.…”
Section: Discussionmentioning
confidence: 99%
“…The wear rates for the tested materials can be seen in Figures 1, 3, 5, and 7 and the friction coefficient values during the tests can be seen in Figures 2,4,6,and 8. When the deva.bm friction material is used in water, the test is stopped after around one hour of testing due to a rapid increase in the friction coefficient and wear rate (see Figures 1 and 2). The deva.bm bearing material shows steady friction coefficient values of about 0.2 ± 0.05 during the test under dry operating conditions ( Figure 2).…”
Section: Friction and Wearmentioning
confidence: 99%
See 1 more Smart Citation