2013
DOI: 10.1159/000351459
|View full text |Cite
|
Sign up to set email alerts
|

Luminex® and Its Applications for Solid Organ Transplantation, Hematopoietic Stem Cell Transplantation, and Transfusion<sup>*</sup>

Abstract: The detection of antibodies against the human leukocyte antigen (HLA) complex has become indispensable in every clinical practice. The development of solid-phase assays like the Luminex allows the standardized measurement of anti-HLA antibodies (HLAab) with high sensitivity, albeit the relevance for some clinical settings remains a matter of debate. In this review we aim to describe the principle of Luminex-based antibody detection, including two modifications that allow identifying solely complement-activatin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
28
0
2

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
3
1

Relationship

1
9

Authors

Journals

citations
Cited by 80 publications
(37 citation statements)
references
References 62 publications
1
28
0
2
Order By: Relevance
“…Phenotypic or multi-antigen beads contain Class I and Class II antigens from a single cell line, while each SAB contains a single HLA antigen(8). In both cases, the beads contain a unique ratio of different fluorochromes that provide a distinctive signal that is recognized by Luminex® technology(8). The patient's serum is incubated with the solid phase platform (beads) and a fluorescent-conjugated anti-human IgG, which binds to alloantibody bound to its antigenic target.…”
Section: The Solid Phase Single Antigen Bead (Sab) Assaysmentioning
confidence: 99%
“…Phenotypic or multi-antigen beads contain Class I and Class II antigens from a single cell line, while each SAB contains a single HLA antigen(8). In both cases, the beads contain a unique ratio of different fluorochromes that provide a distinctive signal that is recognized by Luminex® technology(8). The patient's serum is incubated with the solid phase platform (beads) and a fluorescent-conjugated anti-human IgG, which binds to alloantibody bound to its antigenic target.…”
Section: The Solid Phase Single Antigen Bead (Sab) Assaysmentioning
confidence: 99%
“…25,26 A threshold of 1,000 mean fluorescence intensity (MFI) was used to define anti-HLA antibody positivity. The highest MFI value was considered in patients who showed DSA against more than one antigen.…”
Section: Dsa Detection and Therapymentioning
confidence: 99%
“…18,19 Conversely, new methodologies such as the Luminex platform have demonstrated both a greater sensitivity and an unambiguous recognition of antibodies against one or both classes. 20 The use of bead-based Luminex screening in laboratories has become widespread worldwide and has improved the detection of anti-HLA antibodies. In this context, to improve our understanding of the limitations but also of the potential of Luminex-based technology, we focused our study on interpretative and technical aspects regarding its use.…”
Section: Discussionmentioning