2021
DOI: 10.15583/jpchrom.2021.008
|View full text |Cite
|
Sign up to set email alerts
|

LVSEP Analysis of Cationic Analytes in Cationic Polymer-Coating Microchannel Prepared by Vacuum-Drying Method

Abstract: To improve the detection sensitivity of cationic analytes with simple experimental procedures in microchip electrophoresis (MCE), large-volume sample stacking with an electroosmotic flow (EOF) pump (LVSEP) was performed in polymer-coated microchannels. At first, cationic polybrene (PB) was employed as the coating polymer to reverse the EOF. In the LVSEP analyses, however, the PB-coated microchannel gave insufficient enrichments and broader peaks for cationic standard dyes. By the application of neutral poly(vi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 35 publications
1
7
0
Order By: Relevance
“…MCE experiments were performed with the same apparatus as the previous report [10]. In the LVSEP analysis on the straight-channel chip, a sample solution was introduced into the entire channel by manually using a syringe.…”
Section: Mce Measurementsmentioning
confidence: 99%
See 3 more Smart Citations
“…MCE experiments were performed with the same apparatus as the previous report [10]. In the LVSEP analysis on the straight-channel chip, a sample solution was introduced into the entire channel by manually using a syringe.…”
Section: Mce Measurementsmentioning
confidence: 99%
“…To overcome this limitation, various on-line sample preconcentration methods have been developed [3][4][5][6][7][8]. In our research group, a large volume sample stacking with electroosmotic flow pump (LVSEP) technique has been applied to enhance the sensitivities [9][10][11][12][13][14][15][16][17][18][19]. LVSEP involves the enrichment of the sample injected into the whole separation column by the field-amplified sample stacking, and the separation of the focused analytes without polarity switching due to the changes in the velocity of electroosmotic flow (EOF) between at the stacking and at the separation step.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Liquid chromatography (LC) and capillary electrophoresis (CE) are methods used for separating a wide variety of compounds, and both fundamental and applicational studies are still progressing [1][2][3][4][5][6][7][8][9][10][11]. Focused on polymers as analytes, biopolymers such as proteins and DNAs have been separated frequently in both LC and CE, and many analytical protocols have been developed.…”
Section: Introductionmentioning
confidence: 99%