2013
DOI: 10.1080/15422119.2013.794148
|View full text |Cite
|
Sign up to set email alerts
|

Magnetic Field Application and its Potential in Water and Wastewater Treatment Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
99
1
2

Year Published

2015
2015
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 218 publications
(103 citation statements)
references
References 131 publications
1
99
1
2
Order By: Relevance
“…BaSO 4 and BaSO 4 took 51 ± 2 min and 23.0 ± 0.5 min, respectively. Curiously, BaSO 4 took 30 ± 4 min, indicating that the effect of MF on Ba 2+ (cation) is stronger than that on SO 4 2− (anion) and the colloidal stability of BaSO 4 dispersions was slightly higher than that of BaSO 4 dispersions. In the case of silver chloride insoluble salts, the treatment with MF had no significant effect on the colloidal stability, because dispersions of AgCl, AgCl and AgCl took 24 ± 1 min, 22 ± 1 min and 21 ± 1 min, respectively, to achieve 30% of transmittance.…”
Section: Resultsmentioning
confidence: 91%
See 2 more Smart Citations
“…BaSO 4 and BaSO 4 took 51 ± 2 min and 23.0 ± 0.5 min, respectively. Curiously, BaSO 4 took 30 ± 4 min, indicating that the effect of MF on Ba 2+ (cation) is stronger than that on SO 4 2− (anion) and the colloidal stability of BaSO 4 dispersions was slightly higher than that of BaSO 4 dispersions. In the case of silver chloride insoluble salts, the treatment with MF had no significant effect on the colloidal stability, because dispersions of AgCl, AgCl and AgCl took 24 ± 1 min, 22 ± 1 min and 21 ± 1 min, respectively, to achieve 30% of transmittance.…”
Section: Resultsmentioning
confidence: 91%
“…The transmittance profiles (Fig. 2a) and photographs of dispersions of BaSO 4 and BaSO 4 at t = 0 min (Fig. 2b) and after 60 min (Fig.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Especially, magnetic fields (MFs) stimulation offers a potentially low-cost and convenient approach to enhance microbial activity, since a static MF can be continuously and conveniently applied to any biosystem without need for extra energy input (Ji et al 2010;Filipic et al 2012). Previous studies have demonstrated that implementation of an appropriate MF could raise microbial activity and accelerate contaminant degradation in wastewater treatment systems Kriklavova et al 2014;Zaidi et al 2014). MFs have also been found to promote bioelectrocatalytic activities of several enzyme assemblies linked to electrodes through accelerating electron transfer at electrode-solution interfaces (Katz et al 2005).…”
Section: Introductionmentioning
confidence: 99%
“…In this method, large gradients are produced in a magnetic field around magnetically susceptible wires. [1] The magnetic force acting on the magnetized particles can be expressed by Equation (1) as follows:…”
Section: Introductionmentioning
confidence: 99%