2001
DOI: 10.1002/er.762
|View full text |Cite
|
Sign up to set email alerts
|

Magnetic field of high-phase order and compact transmission lines

Abstract: SUMMARYResearch has been conducted in high phase order (HPO) power transmission wherein 6 or 12 phases are used to transmit power in less physical space and with reduced environmental e!ects than conventional designs. In this paper, existing 3-phase double circuit transmission lines (TL) are recon"gured to 6-phase systems for the purpose of calculating and comparing the magnetic "eld of both systems. The magnetic "eld of several single-phase con"gurations; #at, vertical, delta and inverted-delta with the same … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(6 citation statements)
references
References 8 publications
0
6
0
Order By: Relevance
“…However, multi-circuit overhead lines are also utilized in Kuwait, India, China, and Malaysia. [3][4][5][6] Fault location is well studied for single-circuit [7][8][9][10][11][12][13][14][15][16] and double-circuit [17][18][19][20][21][22][23][24] series-compensated transmission lines (SCTLs) compared with multi-circuit SCTLs. In Saha et al, 7 one-terminal measurements in the phase domain are used to determine the fault location for single-circuit SCTL.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, multi-circuit overhead lines are also utilized in Kuwait, India, China, and Malaysia. [3][4][5][6] Fault location is well studied for single-circuit [7][8][9][10][11][12][13][14][15][16] and double-circuit [17][18][19][20][21][22][23][24] series-compensated transmission lines (SCTLs) compared with multi-circuit SCTLs. In Saha et al, 7 one-terminal measurements in the phase domain are used to determine the fault location for single-circuit SCTL.…”
Section: Discussionmentioning
confidence: 99%
“…Recently, single‐ and double‐circuit overhead lines are widely spread in most countries. However, multi‐circuit overhead lines are also utilized in Kuwait, India, China, and Malaysia . Fault location is well studied for single‐circuit and double‐circuit series‐compensated transmission lines (SCTLs) compared with multi‐circuit SCTLs.…”
Section: Introductionmentioning
confidence: 99%
“…The mutual impedances between phases of one line are eliminated first, and then the line-to-line mutual impedances are decoupled. The mutual impedances between phases can be eliminated by the symmetrical components shown in (3). The transforming matrix for symmetrical method for double-circuit line is the matrix Q, where a = e j 120 • = −1/2 + j ( √ 3/2).…”
Section: New Decoupling Methods For Double-circuit Linementioning
confidence: 99%
“…With the development of modern society, it is necessary to expand the power transmission capacity. The available land areas are shrinking, so the high phase order transmission system is considered as an alternative for increasing the power transmission capability [1][2][3]. Double-circuit transmission lines on the same tower can efficiently cut down the electric power infrastructure cost and enhance the capability of transmission lines.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, doublecircuit HV transmission lines have become very common in many countries. Four-circuit transmission lines, which are also known as quadruple transmission lines in a single tower, are used more and more widely in Asian countries such as Malaysia, India, Kuwait and China [1][2][3][4][5]. The main advantage of using a four-circuit transmission line is that it helps to solve the environmentally related problems such as earth geography and land availability.…”
Section: Introductionmentioning
confidence: 99%