1980
DOI: 10.1109/tmag.1980.1060810
|View full text |Cite
|
Sign up to set email alerts
|

Magnetic measurement of human iron stores

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
22
0

Year Published

1994
1994
2018
2018

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 47 publications
(22 citation statements)
references
References 5 publications
0
22
0
Order By: Relevance
“…Today's clinical susceptometers use SQUID magnetic sensors and superconducting field coils enclosed in a liquid-helium dewar (Farrell et al 1980, Paulson et al 1991. This classic design has been validated by liver biopsy (Fischer et al 1992, Brittenham et al 1982, used clinically on hundreds of patients, and subjected to an intensive analysis of measurement errors (Fischer et al 1999(Fischer et al , 2002.…”
Section: Background and Motivationmentioning
confidence: 99%
See 1 more Smart Citation
“…Today's clinical susceptometers use SQUID magnetic sensors and superconducting field coils enclosed in a liquid-helium dewar (Farrell et al 1980, Paulson et al 1991. This classic design has been validated by liver biopsy (Fischer et al 1992, Brittenham et al 1982, used clinically on hundreds of patients, and subjected to an intensive analysis of measurement errors (Fischer et al 1999(Fischer et al , 2002.…”
Section: Background and Motivationmentioning
confidence: 99%
“…Based on measurements by Farrell et al (1980), this model assumes that the response of the susceptometer falls off exponentially with distance. It represents the susceptometer response as…”
Section: 33mentioning
confidence: 99%
“…Because the lungs (and possibly gas-filled intestines) are not directly beneath the detector, their contribution is small even though they can have a susceptibility substantially different from that of water. The susceptometer design and the differential measurement technique developed by Farrell and his colleagues [1,2,3,4] has been used as the basis for all commercial susceptometers [13]. The principal limitations on the use of susceptometry are in individuals who are obese, very small, or those who have metal implants or devices that may not be removed prior to the study.…”
Section: Principlesmentioning
confidence: 99%
“…Death is usually the result of cardiac failure. Bauman and Harris [2] originally proposed that the paramagnetic properties of storage iron (ferritin and hemosiderin) could be used to assess the body iron burden non-invasively. Harris and his co-workers subsequently developed low-transition-temperature (low-T C ; operating at 4°K in liquid helium) superconducting quantum interference device (SQUID) biosusceptometry as a clinical method for the measurement of hepatic iron stores [3].…”
Section: Introductionmentioning
confidence: 99%
“…System design and the ambient fields in the vicinity of the probe determine noise levels. With the use of gradiometer configuration pickup coils, signal levels on the order of 2 ϫ 10 −14 T / cm are readily achievable 11 in an unscreened relatively low noise environment.…”
Section: Introductionmentioning
confidence: 99%