Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
96
1

Year Published

2017
2017
2022
2022

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 77 publications
(98 citation statements)
references
References 25 publications
1
96
1
Order By: Relevance
“…Additionally, the PTV margins chosen for this study were conservative, at 0.5 cm from the GTV, an expansion that was selected to match that of typical CT-guided SBRT, in order to avoid excessive departures from standard-ofcare SBRT practice in this first application of SMART. However, given the soft tissue visualization improvements of MR-IGRT, reduced PTV margin size has now been applied in select MR-guided scenarios and is of ongoing interest in future studies [35].…”
Section: Discussionmentioning
confidence: 99%
“…Additionally, the PTV margins chosen for this study were conservative, at 0.5 cm from the GTV, an expansion that was selected to match that of typical CT-guided SBRT, in order to avoid excessive departures from standard-ofcare SBRT practice in this first application of SMART. However, given the soft tissue visualization improvements of MR-IGRT, reduced PTV margin size has now been applied in select MR-guided scenarios and is of ongoing interest in future studies [35].…”
Section: Discussionmentioning
confidence: 99%
“…According to their results, the mean difference between planned and delivered dose was within 1 %. [26] Similarly, another group used MRI with two time scales (2D and 3D MRI) showing a median deviation of about 2 vs. 2.2 mm. [27] MR-imaging during RT represents an elegant and promising approach to track target volumes in real time, especially in soft tissues including breast.…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, pre- and post-treatment acquisitions cannot capture intra-fractional breast motion. Real-time magnetic resonance image (MRI) has also been reported to track breast motion [ 21 , 22 ], though MRI can provide superior soft-tissue contrast of the tumor bed, the reported studies are merely focused on intra-fractional motion using 2D MRI images with limited resolution (e.g. 3.5 mm × 3.5 mm in [ 21 ]).…”
Section: Discussionmentioning
confidence: 99%
“…Real-time magnetic resonance image (MRI) has also been reported to track breast motion [ 21 , 22 ], though MRI can provide superior soft-tissue contrast of the tumor bed, the reported studies are merely focused on intra-fractional motion using 2D MRI images with limited resolution (e.g. 3.5 mm × 3.5 mm in [ 21 ]). In contrast, the near real-time fiducial positions logged by the Cyberknife kV imaging system offer complete data set on breast target geometric changes during the course of treatment, allowing a comprehensive study of breast target geometric errors.…”
Section: Discussionmentioning
confidence: 99%