2004
DOI: 10.1258/000456304322880050
|View full text |Cite
|
Sign up to set email alerts
|

Major method-specific differences in the measurement of intact parathyroid hormone: studies in patients with and without chronic renal failure

Abstract: Background Following the introduction of two-site immunometric assays for parathyroid hormone (PTH), the expectation of good inter-assay agreement has not been fulfilled. The reasons for this may include differences in standardization as well as fragment recognition between the assays.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0
1

Year Published

2006
2006
2012
2012

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(12 citation statements)
references
References 12 publications
0
11
0
1
Order By: Relevance
“…For both primary and renal HPT several intraoperative PTH assays have been described, but the different assays have only been directly compared in a small number of studies (13,18,22,(24)(25)(26)(27). The Immulite Turbo DPC assay is established for both primary HPT (24,28) and renal HPT (12).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…For both primary and renal HPT several intraoperative PTH assays have been described, but the different assays have only been directly compared in a small number of studies (13,18,22,(24)(25)(26)(27). The Immulite Turbo DPC assay is established for both primary HPT (24,28) and renal HPT (12).…”
Section: Discussionmentioning
confidence: 99%
“…Comparing both methods in terms of recovery of the C-terminal fragments of PTH (7-84), which are eliminated by glomerular filtration, Souberbielle et al (30) described a recovery of synthetic PTH (7-84) in 87.6% as measured with the ADVIA Centaur assay. For the Immulite assay, a recovery of PTH (7-84) was described in 62.7% by Worth et al (27). The different percentage of measuring PTH (7-84) with both assays showing a higher cross reactivity for the ADVIA Centaur assay might explain why this assay declined slower into the normal range in patients with impaired renal function compared with the Immulite assay.…”
Section: Discussionmentioning
confidence: 99%
“…Ces techniques sont calibrées contre de la PTH 1-84 synthé-tique d'origines variées, et il n'y a actuellement pas de standard international de PTH 1-84 synthétique. Si un tel standard devient disponible, il faudra intégrer dans les procédures de calibration l'interférence d'un possible effet matrice [41] ainsi que l'instabilité de la PTH synthétique lorsqu'elle est conservée pendant de longues périodes [42]. Enfin, si on montre de manière indiscutable qu'elles mesurent exactement les mêmes molécules, les techniques de troisième génération peuvent permettre de vraiment standardiser les résultats de PTH [43].…”
Section: Aspects Analytiques Et Préanalytiques Des Différentes Généraunclassified
“…In the literature, there is only one reference dealing with the stability of PTH standards under different temperature conditions. 2 Our laboratory includes an aliquot of a human plasma pool 3 as an internal control. This pool is prepared from samples from different patients.…”
Section: Introductionmentioning
confidence: 99%