2019
DOI: 10.1177/1469066719865265
|View full text |Cite
|
Sign up to set email alerts
|

MALDI-TOF mass spectrometry-based quantification of C-peptide in diabetes patients

Abstract: Background Serum C-peptide concentrations reflect insulin secretion and beta cell function and can be used to diagnose and distinguish type-1 and type-2 diabetes. C-peptide is a more accurate indicator of insulin status than direct insulin measurement for monitoring patients with diabetes. However, the current methods available for C-peptide quantification exhibit poor reproducibility, are costly, and require highly trained laboratory personnel. Here, we have developed and evaluated a matrix-assisted laser des… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 29 publications
0
3
0
Order By: Relevance
“…Compared to immunoassays it is more expensive and tedious. [45] Urine [ 13 C 6 Leu 26 , 30 ] Cp PP/ SPE (Waters MCX) Orbitrap Exploris 480 HR-MS (Thermo) ESI(+) ID-LC-MS/MS N/A This procedure is non-invasive. The SP procedure is simple and inexpensive.…”
Section: Id-lc-ms/ms In C-peptide Measurementmentioning
confidence: 99%
See 1 more Smart Citation
“…Compared to immunoassays it is more expensive and tedious. [45] Urine [ 13 C 6 Leu 26 , 30 ] Cp PP/ SPE (Waters MCX) Orbitrap Exploris 480 HR-MS (Thermo) ESI(+) ID-LC-MS/MS N/A This procedure is non-invasive. The SP procedure is simple and inexpensive.…”
Section: Id-lc-ms/ms In C-peptide Measurementmentioning
confidence: 99%
“… Derivatization . This approach is commonly used for target compounds in GC–MS measurement procedures, but derivatization is also quite useful to enhance signals in LC-MS/MS for C-peptide [45] . In 2014, Kinumi et al used 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) to modify the N-terminal amino group of C-peptide, which dramatically increased fragmentation efficiency by adding a positive charge to the peptide.…”
Section: Id-lc-ms/ms In C-peptide Measurementmentioning
confidence: 99%
“…The published method gives multiple warnings on critical steps throughout the procedure and on the several sources of possible error [ 9 ]. Other recent studies address the quantification in human blood of peptides and proteins, such as a phosphorylated amyloid peptide [ 10 ], monoclonal free light chains [ 11 ], C-peptide [ 12 ], isoforms of glutathione-S-transferase [ 13 ] and glycated hemoglobin [ 14 , 15 ].…”
Section: Introductionmentioning
confidence: 99%