2021 IEEE 48th Photovoltaic Specialists Conference (PVSC) 2021
DOI: 10.1109/pvsc43889.2021.9518938
|View full text |Cite
|
Sign up to set email alerts
|

Manufacturing Induced Bending Stresses: Glass-Glass vs. Glass-Backsheet

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(11 citation statements)
references
References 21 publications
2
9
0
Order By: Relevance
“…These results are remarkably consistent with Xray topography and modeling showing higher maximum principal cell stress in glass-glass modules, with highest bending stress concentration in glass-glass modules near the end of ribbon on both ends of the cell. 9 Our results are also consistent with studies examining interconnect failure that shows higher mechanical loads on the solder interconnects leading to double the accumulated plastic strain in glass-glass modules compared with modules with polymeric substrates. 10 Analyzing our observations in the framework of these prior publications, it appears that the stress imparted by the thermal coefficient of expansion mismatch between cells and the copper ribbons led to the fracture of embrittled grid fingers near the ribbon-cell connections.…”
Section: Grid Finger Breakssupporting
confidence: 91%
See 2 more Smart Citations
“…These results are remarkably consistent with Xray topography and modeling showing higher maximum principal cell stress in glass-glass modules, with highest bending stress concentration in glass-glass modules near the end of ribbon on both ends of the cell. 9 Our results are also consistent with studies examining interconnect failure that shows higher mechanical loads on the solder interconnects leading to double the accumulated plastic strain in glass-glass modules compared with modules with polymeric substrates. 10 Analyzing our observations in the framework of these prior publications, it appears that the stress imparted by the thermal coefficient of expansion mismatch between cells and the copper ribbons led to the fracture of embrittled grid fingers near the ribbon-cell connections.…”
Section: Grid Finger Breakssupporting
confidence: 91%
“…Modules with polymeric backsheets also have encapsulant shrinking as temperature is reduced where the backsheet elastically deforms to accommodate the contraction moreso than glass substrates. 9 A previous study stress testing modules by damp heat also showed grid finger interrupts near the copper interconnect ribbon to a significantly greater extent in glass-glass modules compared with modules with polymeric backsheet. 11 Additionally, it has been suggested that the highest bending stresses in glass-glass modules exist when there is pinching at the module edges.…”
Section: Grid Finger Breaksmentioning
confidence: 85%
See 1 more Smart Citation
“…The debond energies after aging were higher than the delamination threshold of 200 J/m 2 found by Bosco et al, 33 which was developed for fielded G/B modules. In the case of G/G modules, the stresses acting upon the interfaces are expected to be somewhat higher, 8 , 34 requiring a greater interfacial debond energy to prevent delamination. Ultimately, these results represent only DH and DH/voltage conditions, so sequential accelerated test sequences involving mechanical stressors and thermal cycling are recommended to further characterize the risk of delamination in fielded G/G modules.…”
Section: Resultsmentioning
confidence: 99%
“…The GT/POE module also displayed minor grid finger detachment or breakage in cells below the junction box. The failures in metal fingers might lead to increase in the series resistance (RS), and hotspots if the degradation becomes severe [6].…”
Section: ) Tc Extended (Tc600)mentioning
confidence: 99%