2021
DOI: 10.1016/j.jare.2019.10.009
|View full text |Cite
|
Sign up to set email alerts
|

Mapping metabolome changes in Luffa aegyptiaca Mill fruits at different maturation stages via MS-based metabolomics and chemometrics

Abstract: Graphical abstract

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 23 publications
(13 citation statements)
references
References 40 publications
0
12
1
Order By: Relevance
“…Chromatographic separation was performed on an ACQUITY UPLC system (Waters, Milford, MA, USA) equipped with a HSS T3 column (100 × 1.0 mm, particle size 1.8 µm; Waters) followed the procedure described in Maamoun , et al [ 85 ]. The analysis was carried out using a binary gradient elution system at a flow rate of 150 µL/min: 0 to 1 min, isocratic 95% A (water/formic acid, 99.9/0.1 [ v / v ]), 5% B (acetonitrile/formic acid, 99.9/0.1 [ v / v ]); 1 to 16 min, linear from 5% to 95% B; 16 to 18 min then isocratic 95% B; 18 to 20 min, and finally, isocratic 5% B.…”
Section: Methodsmentioning
confidence: 99%
“…Chromatographic separation was performed on an ACQUITY UPLC system (Waters, Milford, MA, USA) equipped with a HSS T3 column (100 × 1.0 mm, particle size 1.8 µm; Waters) followed the procedure described in Maamoun , et al [ 85 ]. The analysis was carried out using a binary gradient elution system at a flow rate of 150 µL/min: 0 to 1 min, isocratic 95% A (water/formic acid, 99.9/0.1 [ v / v ]), 5% B (acetonitrile/formic acid, 99.9/0.1 [ v / v ]); 1 to 16 min, linear from 5% to 95% B; 16 to 18 min then isocratic 95% B; 18 to 20 min, and finally, isocratic 5% B.…”
Section: Methodsmentioning
confidence: 99%
“…The negative and positive ion high‐resolution ESI and collision‐induced dissociation (CID) MSn spectra were obtained from an Orbitrap Elite mass spectrometer (Thermo Fisher Scientific, Darmstadt, Germany) equipped with a heated electrospray ion source (negative spray voltage of 3 kV, positive 4 kV, capillary temperature of 300°C, source heater temperature of 250°C, FTMS resolution of 30.000). All conditions were mentioned by Farag, Gad, Heiss, and Wessjohann (2014) and Maamoun, El‐akkad, and Farag (2019).…”
Section: Methodsmentioning
confidence: 99%
“…The CID mass spectra (buffer gas: helium) were recorded by a normalized collision energy (NCE) of 35%. The UV-VIS spectra of LCE were monitored at 254 nm, and the identification of components in LCE was conducted in accordance with the dictionary of natural products (DNP) and previous studies (Maamoun et al, 2021). Data analysis was conducted using Xcalibur 3.0 software (Thermo Fisher).…”
Section: Uhplc-dad-hrms Analysismentioning
confidence: 99%