1993
DOI: 10.1007/bf00549792
|View full text |Cite
|
Sign up to set email alerts
|

Masonry fireplace emissions test method: Repeatability and sensitivity to fueling protocol

Abstract: A test method for masonry fireplaces has been evaluated during testing on six masonry fireplace configurations. The method determines carbon monoxide and particulate matter emission rates (g/h) and factors (g/kg) and does not require weighing of the appliance to determine the timing of fuel loading.The intralaboratory repeatability of the test method has been determined from multiple tests on the six fireplaces. For the tested fireplaces, the ratio of the highest to lowest measured PM rate averaged 1.17 and in… Show more