2015
DOI: 10.1016/j.ijms.2015.06.010
|View full text |Cite
|
Sign up to set email alerts
|

Mass spectrometry signal enhancement by reductive amination

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 23 publications
0
5
0
Order By: Relevance
“…Dimethyl-labeling (DM) is frequently used as a labeling strategy, while the most prominent application is the multiplex quantification of proteins . In a different approach the reductive methylation of amines was performed prior to modification of carboxyl groups to analyze proteins’ carboxy termini …”
Section: Introductionmentioning
confidence: 99%
“…Dimethyl-labeling (DM) is frequently used as a labeling strategy, while the most prominent application is the multiplex quantification of proteins . In a different approach the reductive methylation of amines was performed prior to modification of carboxyl groups to analyze proteins’ carboxy termini …”
Section: Introductionmentioning
confidence: 99%
“…The integrated and statistical results, including the average integrated area, relative standard deviation, and signal enhancement, are shown in Table 2 . We have previously discussed the factor that enhances signals via reductive amination [ 40 ]. We estimated that the factor is the amine group showing a higher electronic density after modification with two methyl groups, causing the lone pair in the amine group to show a more basic quality.…”
Section: Resultsmentioning
confidence: 99%
“…Herein, we used isotopic formaldehyde and sodium cyanoborohydride to generate two methyl groups on the amine functional group of TRP, 5-HTP, and serotonin. This modification, with cheap and easily obtained materials, showed signal enhancement and helped target molecules to be monitored [ 40 ]. Eventually, we establish the derivatized method by estimating calibration curves, the limit of detection (LOD), the limit of quantification (LOQ), intra-day precision, and inter-day precision.…”
Section: Introductionmentioning
confidence: 99%
“…The internal standards were used to normalize PHE and TYR signals, [18][19][20][21][22][23] and formaldehydemodified PHE and TYR were detected by mass spectrometry signal enhancement. 24 We compared the concentrations of plasma on filter paper and crude plasma samples and used HPLC-MS/MS to monitor derivatized PHE and TYR in the plasma samples. The results showed no obvious differences.…”
Section: Introductionmentioning
confidence: 99%