2020
DOI: 10.1016/j.egyr.2020.11.016
|View full text |Cite
|
Sign up to set email alerts
|

Mass transfer model of fracture-controlled matrix unit: Model derivation and experimental verification based on fractal theory and micro-CT scanning technology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
3
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 16 publications
(4 citation statements)
references
References 74 publications
0
3
0
Order By: Relevance
“…Near-wellbore measurement methods often use radiotracers to monitor wellbore data (Guo et al, 2019;Liu et al, 2018;Jin et al, 2021;Liu et al, 2020a). Different radioactive materials were put into the fracturing fluids, gamma spectrum was measured by using a logging instrument, the distribution of the proppant was obtained, and then the fracture height and width were calculated (Gulrajani and Romero, 1996;Shi et al, 2017;Liu et al, 2020b), as shown in Figure 1C. Near-wellbore measurement technology is limited by a small monitoring range, resulting in low accuracy of evaluation results.…”
Section: Near-wellbore Measurement Methodsmentioning
confidence: 99%
“…Near-wellbore measurement methods often use radiotracers to monitor wellbore data (Guo et al, 2019;Liu et al, 2018;Jin et al, 2021;Liu et al, 2020a). Different radioactive materials were put into the fracturing fluids, gamma spectrum was measured by using a logging instrument, the distribution of the proppant was obtained, and then the fracture height and width were calculated (Gulrajani and Romero, 1996;Shi et al, 2017;Liu et al, 2020b), as shown in Figure 1C. Near-wellbore measurement technology is limited by a small monitoring range, resulting in low accuracy of evaluation results.…”
Section: Near-wellbore Measurement Methodsmentioning
confidence: 99%
“…Abbasi et al 34 studied the effect of dynamic capillary pressure on the two-phase flow process, and the results show that considering the dynamic capillary effect is very important in the simulation of imbibition in porous media. Based on fractal theory, Liu et al 35 deduced the effective mass transfer model of a matrix considering roughness, heterogeneity of pore structure, irreducible water, and pore water pressure and verified the calculation results of the model through threedimensional reconstructed CT images. Other studies have focused on changing materials and their parameters and wetting fluid properties to explore the relationship between imbibition characteristics, materials, and fluids.…”
Section: Introductionmentioning
confidence: 98%
“…Berg and Dalton et al [33,34] obtained an accurate complex pore structures of sandstone and investigated the effects of permeability and wettability on CO2 flow behavior. Liu et al [35,36] first used a new reconstruction method to establish the fracture-controlled matrix unit then used the CT scanning technique to obtain the relevant parameters of the proposed fracture control matrix unit mass transfer model. The correctness of the model was verified by comparison with the experimental results of microscopic spontaneous imbibition.…”
Section: Introductionmentioning
confidence: 99%