Matching geometry and stimulation parameters of electrodes for deep brain stimulation experiments—Numerical considerations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
47
0

Year Published

2008
2008
2021
2021

Publication Types

Select...
6
2
1

Relationship

2
7

Authors

Journals

citations
Cited by 49 publications
(48 citation statements)
references
References 42 publications
1
47
0
Order By: Relevance
“…Electrical stimulation was delivered via concentric bipolar electrodes (CBASC75; FHC), the detailed electrical properties of which have been described previously (Gimsa et al, 2005(Gimsa et al, , 2006. Electrode integrity was verified by impedance measurement.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Electrical stimulation was delivered via concentric bipolar electrodes (CBASC75; FHC), the detailed electrical properties of which have been described previously (Gimsa et al, 2005(Gimsa et al, , 2006. Electrode integrity was verified by impedance measurement.…”
Section: Methodsmentioning
confidence: 99%
“…Current (0 -500 A), duration (30 -120 min), and laterality (unilateral or bilateral) of stimulation varied by experiment. Charge density, calculated using electrode geometry (McCreery et al, 1990;Gimsa et al, 2005Gimsa et al, , 2006, was kept below 30 C/cm 2 /phase to minimize the risk of stimulation-induced neural injury (McCreery et al, 1990).…”
Section: Methodsmentioning
confidence: 99%
“…The distribution of the electric potential in the vicinity of a DBS electrode has previously been modelled using isotropic homogenous tissue [8][9][10][11][12][13][14][15][16]. More recently, Butson et al [17] presented a three dimensional (3D) patient-specific method to predict the volume of tissue activated by DBS based on diffusion tensor images (DTI).…”
Section: Introductionmentioning
confidence: 99%
“…Clinical DBS devices commonly use constant-voltage stimulation, whereas constant-current stimulation guarantees constant field strengths and stimulation efficiency in the surrounding tissue of small animal electrodes by circumventing the effects of impedance alterations at the electrode interface or in the capsule (adventitia) tissue [5]. Studies have demonstrated that current-controlled devices may also improve the therapeutic effects in patients [6][7][8][9].…”
Section: Introductionmentioning
confidence: 99%