2023
DOI: 10.5185/amlett.2023.011713
|View full text |Cite
|
Sign up to set email alerts
|

Material-oriented engineering for eco-optimized structures—a new design approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 25 publications
0
2
0
Order By: Relevance
“…As part of the research project [23], this study highlighted the potential of stainless 304 steel ribbed bars for developing protective refractory shells. Still, reducing the scatter of the pull-out test results (Figure 4d and Table 3) is needed for a reliable bond model.…”
Section: Further Investigationmentioning
confidence: 98%
See 1 more Smart Citation
“…As part of the research project [23], this study highlighted the potential of stainless 304 steel ribbed bars for developing protective refractory shells. Still, reducing the scatter of the pull-out test results (Figure 4d and Table 3) is needed for a reliable bond model.…”
Section: Further Investigationmentioning
confidence: 98%
“…This study belongs to a research project [23] developing fire protection systems with refractory protective shells. This manuscript investigates the bond performance of steel bars in refractory castables through pull-out tests of smooth and ribbed reinforcement bars.…”
Section: Introductionmentioning
confidence: 99%
“…Technology development provides various materials for reinforcing and strengthening concrete structures [ 1 , 2 ]. Fiber-reinforced polymers (FRPs) are a promising steel alternative because they are high-strength, lightweight, immune to corrosion, and electromagnetically transparent [ 3 , 4 , 5 , 6 ]. Still, the relatively low resistance to ultraviolet radiation, elevated temperatures, and humidity reduce the mechanical performance of FRP materials with time [ 7 , 8 , 9 ]; the cycling loads complicate the issue, reducing the mechanical resistance of the reinforcement systems even more [ 10 , 11 ].…”
Section: Introductionmentioning
confidence: 99%
“…As mentioned in Section 1.1 and reported in references [ 4 , 36 ], the absence of a uniform testing methodology complicates the comparative analysis of the efficiency of alternative materials and reinforcement layouts reported in the literature. Furthermore, the analysis of full-scale objects is possible but relevant only for the verification of particular solutions.…”
Section: Introductionmentioning
confidence: 99%