Matrix-matched quantitative analysis of trace-elements in calcium carbonate shells by laser-ablation ICP–MS: application to the determination of daily scale profiles in scallop shell (Pecten maximus)

Abstract: A micro-scale method has been developed for analysis of trace-element concentration profiles in the calcium carbonate shell of the Great Scallop (Pecten maximus). UV laser ablation at 266-nm coupled with ICP-MS detection was used to analyse daily calcite striae of shell samples to obtain high temporal resolution of trace element incorporation. Analysis of scallop shells was carefully examined to determine the quality of calcium carbonate ablation and calibration. An accurate external calibration method based o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
74
0
2

Year Published

2007
2007
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 71 publications
(78 citation statements)
references
References 44 publications
2
74
0
2
Order By: Relevance
“…In addition, a low volume ablation cell (3.7 cm 3 ) was used to minimize signal peak broadening and enhance the signal-to-noise ratio. Quantification of trace elements in otoliths was achieved by external calibration using a series of 13 coprecipitated carbonate pellets (Barats et al 2007) ranging from 0.1 to 500 µg g −1 . Matrix matching calibration was preferred over conventional NIST glass sample to ensure the best accuracy.…”
Section: Elemental Analysis With La-icp-msmentioning
confidence: 99%
“…In addition, a low volume ablation cell (3.7 cm 3 ) was used to minimize signal peak broadening and enhance the signal-to-noise ratio. Quantification of trace elements in otoliths was achieved by external calibration using a series of 13 coprecipitated carbonate pellets (Barats et al 2007) ranging from 0.1 to 500 µg g −1 . Matrix matching calibration was preferred over conventional NIST glass sample to ensure the best accuracy.…”
Section: Elemental Analysis With La-icp-msmentioning
confidence: 99%
“…to an ICP-MS (X7 serie, Thermo Fisher). The methodology and validation were described elsewhere and summarized here (Barats et al, 2007). Samples were analysed during 2 min at a scan speed rate of 5 µm/s.…”
Section: Determination Of Ba Concentrations In Shells Bymentioning
confidence: 99%
“…The intensity of each isotope signal was systematically normalized against the 43 Ca signal to compensate for instrumental drift and instability. An external calibration was performed with lab prepared CaCO 3 standards containing Ba concentrations ranging from 0.005 to 19.6 µg/g (Barats et al, 2007). The Ba calibration curve displayed a good linearity with a regression coefficient r 2 above 0.998 (Barats et al, 2007).…”
Section: Determination Of Ba Concentrations In Shells Bymentioning
confidence: 99%
See 2 more Smart Citations