2008
DOI: 10.1016/j.jbiomech.2008.08.018
|View full text |Cite
|
Sign up to set email alerts
|

Matrix mechanical properties of transversalis fascia in inguinal herniation as a model for tissue expansion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
22
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(22 citation statements)
references
References 32 publications
0
22
0
Order By: Relevance
“…Our results do not support the hypothesis that physical exposures lead to formation of medial hernias through a mechanism involving connective tissue degradation and weakening of the transversalis fascia. In accordance with this, a recent study found no differences in key mechanical properties of the transversalis fascia in patients with or without inguinal hernias (unfortunately, the study did not distinguish between medial and lateral hernias) 31. Interestingly (and as noted in the aforementioned recent systematic review,7), two previous studies have observed that lateral hernias were more likely to occur among patients with heavy work 32 33…”
Section: Discussionmentioning
confidence: 59%
“…Our results do not support the hypothesis that physical exposures lead to formation of medial hernias through a mechanism involving connective tissue degradation and weakening of the transversalis fascia. In accordance with this, a recent study found no differences in key mechanical properties of the transversalis fascia in patients with or without inguinal hernias (unfortunately, the study did not distinguish between medial and lateral hernias) 31. Interestingly (and as noted in the aforementioned recent systematic review,7), two previous studies have observed that lateral hernias were more likely to occur among patients with heavy work 32 33…”
Section: Discussionmentioning
confidence: 59%
“…The collagen fibres and fibrils are thinner and unevenly distributed in the rectus sheath of patients with a direct or indirect inguinal hernia compared with people without a hernia 26,31 . The collagen fibril diameter of the rectus sheath in patients with a direct inguinal hernia was thinner than in patients with an indirect inguinal hernia 26 , whereas there was no difference in the transversalis fascia fibril diameter between these groups 32,33 . The amount of interfibrillar matrix of fascia transversalis was higher in patients with a direct inguinal hernia than in individuals with an indirect inguinal hernia 32 .…”
Section: Ultrastructure Of the Abdominal Wallmentioning
confidence: 76%
“…The mechanical properties of abdominal fascia have been investigated using uniaxial tensile tests, punch tests, and elasticity measurements involving a suction device [9][10][11]. Several of these investigations revealed the elastic properties of fascia and its anisotropic behavior-namely, its direction-dependent response to an applied load [11,12].…”
Section: Introductionmentioning
confidence: 99%
“…Several of these investigations revealed the elastic properties of fascia and its anisotropic behavior-namely, its direction-dependent response to an applied load [11,12]. The above-noted uniaxial mechanical tests [12] were used to assess the changes in the elastic properties of abdominal fascia.…”
Section: Introductionmentioning
confidence: 99%