2013 48th International Universities' Power Engineering Conference (UPEC) 2013
DOI: 10.1109/upec.2013.6714912
|View full text |Cite
|
Sign up to set email alerts
|

Measurement and statistical analysis of Partial Discharges at DC voltage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 5 publications
0
4
0
1
Order By: Relevance
“…PD under AC conditions is well understood and is a developed measurement and post analysis process applied to AC equipment. In contrast under DC conditions the same measurement tools are used but the post analysis of PD events is understood in less detail, the main method under investigation being the statistical analysis of the PD activity [7][8][9][10][11].…”
Section: Introductionmentioning
confidence: 99%
“…PD under AC conditions is well understood and is a developed measurement and post analysis process applied to AC equipment. In contrast under DC conditions the same measurement tools are used but the post analysis of PD events is understood in less detail, the main method under investigation being the statistical analysis of the PD activity [7][8][9][10][11].…”
Section: Introductionmentioning
confidence: 99%
“…Despite this, the analysis of DC PD is thought to be a useful indicator over the overall health of a cable and may be a possible indictor of other cables faults that might lead to cable failures. In the past DC PD has been analysed by comparing the discharge amplitudes, and the time between pulses, by these, and other methods, research has determined common patterns for some defect types, including corona, surface and void discharges [5]- [7]. Within cables, partial discharges occur in defects in cable insulation that can be introduced during manufacture, installation or maintenance, void defects are among the most common.…”
Section: Ac Partial Discharge and Testing Methods Are Defined In Iecmentioning
confidence: 99%
“…Spesifikasi teknis baru (IEC 62478) yang juga mencakup metode listrik non-konvensional di samping teknik akustik saat ini sedang dipertimbangkan. Pada masa lalu Partial discharge telah dianalisis dengan membandingkan discharge amplitudo, dan waktu antara beberapa pulsa, beberapa penelitian telah menemukan pola umum untuk beberapa jenis kerusakan akibat partial discharge termasuk corona pada permukaan peralatan dan pelepasan muatan isolasi pada void [5]- [7] Partial Discharge (PD) menyebabkan kerusakan progresif dari bahan isolasi, efek PD pada kabel tegangan tinggi dan peralatan bisa menyebabkan kegagalan isolasi [8]. Efek komulatif dari PD dalam isolasi padat adalah terjadinya proses pemohonan, peristiwa PD yang berulang menyebabkan kerusakan mekanik dan kimia ireversibel dari bahan isolasi.…”
Section: Pendahuluanunclassified