2020
DOI: 10.1109/tste.2019.2948224
|View full text |Cite
|
Sign up to set email alerts
|

Measurement-Based Estimation of Inertia in AC Microgrids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
33
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 96 publications
(33 citation statements)
references
References 29 publications
0
33
0
Order By: Relevance
“…The HEV charging station of locality is considered as the DRS unit in this work for contract-based DSM as modelled in Figure 3d. Net power to be activated by each DRS unit of ith microgrid at any instance (∆P DRi ) could be assessed by the strategy (9) [12,13] considering the change in maximum available DRS (∆P DRMi ) in ith microgrids estimated by (10) based on DRS contract with the charging station of HEV [17,18]. The range of maximum frequency regulation is decided by the utility, and this work considered, ∆f m = 0.05 Hz, where the tie-line loading coefficients (L DRi ) for DRS are proportional controller gains and tuned with optimization techniques [17,18].…”
Section: Demand Response Support Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…The HEV charging station of locality is considered as the DRS unit in this work for contract-based DSM as modelled in Figure 3d. Net power to be activated by each DRS unit of ith microgrid at any instance (∆P DRi ) could be assessed by the strategy (9) [12,13] considering the change in maximum available DRS (∆P DRMi ) in ith microgrids estimated by (10) based on DRS contract with the charging station of HEV [17,18]. The range of maximum frequency regulation is decided by the utility, and this work considered, ∆f m = 0.05 Hz, where the tie-line loading coefficients (L DRi ) for DRS are proportional controller gains and tuned with optimization techniques [17,18].…”
Section: Demand Response Support Systemmentioning
confidence: 99%
“…An extended virtual synchronous generator is proposed for load frequency control (LFC) of microgrids [9]. The inertia of AC microgrid with renewable penetrations is estimated by frequency response measurement using curve-fitting method in [10]. Most of the similar literature have designed VSG with energy storage system (ESS) and fast-acting bidirectional converter to improve the inertia and damping effect of microgrids.…”
Section: Introductionmentioning
confidence: 99%
“…A disturbance observer based method is given in [27] for inertia improvement. In [28], estimation of inertia in AC microgrid is determined. However, in these methods an extra source, reserve ESS, or load curtailment is required to provide inertia.…”
Section: A State Of the Artmentioning
confidence: 99%
“…The swing equation is the basis of most estimates of power system inertia, with [16] providing a good example; however this analysis uses simulated data with a very low noise component. When dealing with real data it is common to employ filters, such as those discussed in [13] - [15].…”
Section: Introductionmentioning
confidence: 99%