2018
DOI: 10.1364/ao.57.008220
|View full text |Cite
|
Sign up to set email alerts
|

Measurement investigation of an off-axis aspheric surface via a hybrid compensation method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…All solvents were used as anhydrous. 1 H-NMR and 13 C-NMR spectra were recorded on a Bruker DRX Avance 300 MHz equipped with a non-reverse probe (BBI). MS analyses were performed by using a Thermo Finnigan (MA, USA) LCQ Advantage system MS spectrometer with an electrospray ionization source and an "Ion Trap" mass analyzer.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…All solvents were used as anhydrous. 1 H-NMR and 13 C-NMR spectra were recorded on a Bruker DRX Avance 300 MHz equipped with a non-reverse probe (BBI). MS analyses were performed by using a Thermo Finnigan (MA, USA) LCQ Advantage system MS spectrometer with an electrospray ionization source and an "Ion Trap" mass analyzer.…”
Section: Methodsmentioning
confidence: 99%
“…To overcome these problems, the introduction of structurally new ligands around the platinum center has been deeply studied. [9][10][11] Also Pt IV compounds have been employed [12,13] as a prodrug that can, upon reduction to Pt II become excellent therapeutic agents. This strategy has indeed shown an excellent reduction of the overall toxicity of the complex in vivo and activation in cancer cells triggered by the presence of the reducing biological molecule, glutathione, GSH.…”
Section: Introductionmentioning
confidence: 99%
“…When the aberration is larger than what a single CGH cannot be compensated, hybrid compensation is a suitable choice. In Figure 4, a fold sphere mirror was used to compensate most of the low-order aberration and a CGH was applied to compensate the residual aberration, which is still a null test system [18]. The function of each element in Figure 4 is similar to that illustrated in Figure 2 The test result of hybrid compensation includes four parts, as seen in Equation 2 (2) In this equation, the definition of each sub-term is similar to that in Equation (1).…”
Section: Hybrid Compensation Methodsmentioning
confidence: 99%
“…Nowadays, they are used as optical surface references, to cope with the production of complex and non-standard optical surfaces (aspherical and free form), which are made possible by new optical fabrication technologies [38]. They are applied to test different optics, even large aspherical mirrors for the new generation telescopes [39,40].…”
Section: Computer-generated Hologramsmentioning
confidence: 99%