2020
DOI: 10.1038/s41598-020-61620-z
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of 10 fs pulses across the entire Visible to Near-Infrared Spectral Range

Abstract: Tuneable ultrafast laser pulses are a powerful tool for measuring difficult-to-access degrees of freedom in materials science. In general these experiments require the ability to address resonances and excitations both above and below the bandgap of materials, and to probe their response at the timescale of the fastest non-trivial internal dynamics. This drives the need for ultrafast sources capable of delivering 10-15 fs duration pulses tuneable across the entire visible (VIS) and near infrared (NIR) range, 5… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
12
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 19 publications
(15 citation statements)
references
References 43 publications
1
12
0
Order By: Relevance
“…It also brings in the ease and flexible range of the needed measurements. For example, if the SH wavelength becomes too large for available spectrometers, we can instead record the TH, and the same is true of the reversed situation 49 .…”
Section: Discussionmentioning
confidence: 99%
“…It also brings in the ease and flexible range of the needed measurements. For example, if the SH wavelength becomes too large for available spectrometers, we can instead record the TH, and the same is true of the reversed situation 49 .…”
Section: Discussionmentioning
confidence: 99%
“…S2 ). Further details of these sources can be found in Johnson et al 45 and Amuah et al 46 An achromatic ultrafast spectroscopy system compatible with few-cycle duration pulses was used to perform the pump-probe measurements at near-normal incidence. The LSMO sample was held in a closed cycle helium cryostat at 180 K, and pump-induced changes to the probe reflectivity were recorded with a pair of diodes sampling the parallel and perpendicular polarization components.…”
Section: Methodsmentioning
confidence: 99%
“…Supplementary Figure S2: Pump and probe pulse durations. a Pump and probe pulses used in the reflection anisotropy setup reconstructed using frequency-resolved optical gating 32 . The 800 nm pulses are of 50 fs duration (full-width half maximum) and the 1500 nm probe pulses are 60 fs duration.…”
Section: Author Contributionsmentioning
confidence: 99%
“…FROG has been implemented using different optical setups and nonlinear processes including collinear setups, where the laser beam paths overlap, for secondharmonic generation (SHG), 3 third-harmonic generation (THG), 4 and noncollinear setups. 5 In an autocorrelation FROG measurement, two copies of the same pulse are combined inside a nonlinear medium. Alternatively, in a crosscorrelation FROG measurement, a known reference pulse is combined with an unknown pulse to generate nondegenerate signals such as sum-frequency generation (SFG) or four-wave mixing (FWM).…”
Section: ■ Introductionmentioning
confidence: 99%