2020
DOI: 10.1515/ract-2019-3189
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of 14.54 MeV neutron induced reaction cross sections of Cr and Mn with covariance analysis

Abstract: The 50Cr(n,2n)49Cr, 52Cr(n,2n)51Cr, 52Cr(n,p)52V, 55Mn(n,2n)54Mn, 55Mn(n,α)52V and 55Mn(n,γ)56Mn reaction cross sections at the neutron energy of 14.54 ± 0.24 MeV were measured by using activation method along with off-line γ-ray spectrometry. The 27Al(n,p)27Mg monitor reaction was used for the 52Cr(n,p)52V and 55Mn(n,α)52V reactions, whereas the 197Au(n,γ)198Au monitor reaction for the 55Mn(n,γ)56Mn reaction. The 27Al(n,α)24Na monitor reaction was used for other three reactions. The neutron beam was generated… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 47 publications
0
6
0
Order By: Relevance
“…The resolution of the HPGe detector had a FWHM of 1.8 keV at the photo-peak of 1332.5 keV γ-ray of 60 Co. Due to low γ-ray activity, the irradiated samples were measured at a distance of 1 cm from the end cap of the detector. The details of neutron energy calculations using GEANT4 simulations are given in our previous publication [26,27].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The resolution of the HPGe detector had a FWHM of 1.8 keV at the photo-peak of 1332.5 keV γ-ray of 60 Co. Due to low γ-ray activity, the irradiated samples were measured at a distance of 1 cm from the end cap of the detector. The details of neutron energy calculations using GEANT4 simulations are given in our previous publication [26,27].…”
Section: Methodsmentioning
confidence: 99%
“…The meaning of terms, micro-correlation and detail calculations are given in refs. [27,31,39,40]. The fractional uncertainties with correlations of different attributes in obtaining the 93 Nb(n,α) 90m Y, 93 Nb(n,2n) 92m Nb and 92 Mo(n,p) 92m Nb reaction cross sections are presented in Table 4.…”
mentioning
confidence: 99%
“…2. The efficiency calibration curve was fitted to a polynomial function to obtain the most accurate values using the following expression [23][24][25]33]:…”
Section: Data Analysis a Efficiency Calibration Of The Detector With ...mentioning
confidence: 99%
“…In addition, the uncertainty accompanying the activation cross-section is essential in determining a reasonable margin, which contributes to both safety and economy in nuclear applications [23,24]. If several data points of the activation cross-sections are involved in determining the quantity of interest, the correlation (covariance) among the data points must also be considered to avoid overestimating or underestimating the uncertainty in the quantity of interest [25].…”
Section: Introductionmentioning
confidence: 99%
“…The details of neutron energy calculations using GEANT4 are given in refs. [27][28][29][30]. A deuterium beam having energy of 180 ± 0.1 keV, with envelope diameter of 0.47 cm, measured using a beam profile monitor on TiT target is simulated in GEANT4.…”
Section: Neutron Generatormentioning
confidence: 99%