2018
DOI: 10.1007/s10967-018-5764-x
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of 151Sm in nuclear decommissioning samples by ICP-MS/MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 20 publications
0
9
0
Order By: Relevance
“…Research fields and objectives. The research fields of the above references covered biology, 1-15 energy, 16 environment, 9,[17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32] food/medical, 10-12,25-27,33-40 geology, 28,41-47 material, [48][49][50][51][52][53][54][55][56][57][58][59][60] and radionulide, 4,[22][23][61][62][63][64][65][66][67][68][69][70][71] respectively. In addition to these conventional elemental analysis topics, a study on the gas phase catalytic reaction has also been reported by using the reaction cell of ICP-QMS/QMS as the in-situ reaction field.…”
Section: References Investigatedmentioning
confidence: 99%
See 1 more Smart Citation
“…Research fields and objectives. The research fields of the above references covered biology, 1-15 energy, 16 environment, 9,[17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32] food/medical, 10-12,25-27,33-40 geology, 28,41-47 material, [48][49][50][51][52][53][54][55][56][57][58][59][60] and radionulide, 4,[22][23][61][62][63][64][65][66][67][68][69][70][71] respectively. In addition to these conventional elemental analysis topics, a study on the gas phase catalytic reaction has also been reported by using the reaction cell of ICP-QMS/QMS as the in-situ reaction field.…”
Section: References Investigatedmentioning
confidence: 99%
“…Many references used He, H2, O2, or NH3, which are usually included as the default cell gas for ICP-QMS/QMS. 4,22,26,44,46,[62][63][64][65][66] There are also multiple references using N2O, 3,23,28,45,68 CO2, 24,27,65 or CH4 43 as the cell gas to improve the separation of spectral interferences. For single element solution, the typical relative uncertainty of isotopic ratio obtained by ICP-QMS/QMS is roughly in the range from 0.1% to 0.2%, which is inferior to that can be achieved by multiple collector (MC-) ICP-MS by 3 to 4 orders of magnitude.…”
Section: Reaction Gases Used In the Measurement By Icp-qms/qmsmentioning
confidence: 99%
“…These authors determined 87 Sr/ 86 Sr ratios directly in certified geological reference materials, BCR‐2 and BHVO‐2, with a precision below 0.1% RSD. The results also showed that the 87 Sr/ 86 Sr ratios of 23 different rock types measured by ICP‐MS/MS and MC‐ICP‐MS methods agreed very well, demonstrating the potential of this method not only in geological studies, but also in other related areas such as environment, agriculture, and nuclear science studies 111,166,175,176,177 . Thus ICP‐MS/MS is set to make greater contributions in geochemical, geochronological, and mineral exploration studies, avoiding the necessity of using a matrix‐matched standard for calibrations.…”
Section: Technological Advances For the Removal Of Interferences In Imentioning
confidence: 68%
“…Nickel-63 is measurable by LSC following chemical separation, achieved by dimethylglyoxime (DMG) precipitation, anion exchange and/or extraction chromatography. [19][20][21][22][23][24] Whilst not being a focus of this study, there is additional interest in measurement of longer lived 59 Ni (half life 76 (5) Â 10 3 a), which has the potential to be a powerful forensic tool through measurement of 59 Ni/ 63 Ni isotopic ratios. Whilst theoretically measurable, 59 Ni suffers from signicant tailing ( 58 Ni), polyatomic ( 58 Ni 1 H) and isobaric ( 59 Co) interferences and there is no known ICP-MS procedure for measuring this radionuclide.…”
Section: Measurement Of Standardsmentioning
confidence: 99%