2019
DOI: 10.1016/j.apradiso.2018.10.013
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of 232Th and 238U neutron capture cross-sections in the energy range 5–17 MeV

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 27 publications
0
9
0
Order By: Relevance
“…The experimental values obtained by Panitkin et al [24] are compatible with the evaluation database CENDL-3.2 but are superior to the ENDF/B-VIII.0 and ROSFOND-2010 [28] databases in the 3.0-7.0 MeV energy region. In contrast, the experimental measurements of Mulik et al [4] at 5.9 ± 0.5 MeV neutron energy and the data of S.Mukherjee et al [7] at 5.1 ± 0.2 MeV are in general accordance with the evaluation databases ENDF/B-VIII.0 and ROSFOND-2010, respectively, yet far inferior to the evaluation data of CENDL-3.2. As stated above, accurate measurements of the reaction cross-sectional values of 238 U (n, γ) 239 U in the 3.0-7.0 MeV neutron energy region are critical for the assessment of cross-section data.…”
Section: Introductionmentioning
confidence: 58%
See 4 more Smart Citations
“…The experimental values obtained by Panitkin et al [24] are compatible with the evaluation database CENDL-3.2 but are superior to the ENDF/B-VIII.0 and ROSFOND-2010 [28] databases in the 3.0-7.0 MeV energy region. In contrast, the experimental measurements of Mulik et al [4] at 5.9 ± 0.5 MeV neutron energy and the data of S.Mukherjee et al [7] at 5.1 ± 0.2 MeV are in general accordance with the evaluation databases ENDF/B-VIII.0 and ROSFOND-2010, respectively, yet far inferior to the evaluation data of CENDL-3.2. As stated above, accurate measurements of the reaction cross-sectional values of 238 U (n, γ) 239 U in the 3.0-7.0 MeV neutron energy region are critical for the assessment of cross-section data.…”
Section: Introductionmentioning
confidence: 58%
“…After the samples had been irradiated for 12 h and cooled for an adequate amount of time (2.7-43 h for Au flakes and 3.5-48 h for U 3 O 8 samples), the characteristic γ-rays produced were measured with a single-ended coaxial low-background GEM30P4-76 HPGe detector with an energy resolution of 850 eV FWHM at 122 keV and 1.85 keV FWHM at 1.33 MeV [6,30] as well as a 30% relative efficiency. The working high voltage was +2 kV, which was provided by ORTEC's 659 highvoltage power supply; the main amplifier 672 (pulse linear amplifier) had an adjustment multiple of 65 times and a time constant of 6 μs.…”
Section: Measurement Of Characteristic γ-Raysmentioning
confidence: 99%
See 3 more Smart Citations