2014
DOI: 10.1088/0029-5515/54/2/023005
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of a 2D fast-ion velocity distribution function by tomographic inversion of fast-ion D-alpha spectra

Abstract: We present the first measurement of a local fast-ion 2D velocity distribution function f (v , v ⊥ ). To this end, we heated a plasma in ASDEX Upgrade by neutral beam injection and measured spectra of fast-ion D α (FIDA) light from the plasma centre in three views simultaneously. The measured spectra agree very well with synthetic spectra calculated from a TRANSP/NUBEAM simulation. Based on the measured FIDA spectra alone, we infer f (v , v ⊥ ) by tomographic inversion. Salient features of our measurement of f … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
97
1
2

Year Published

2014
2014
2024
2024

Publication Types

Select...
9

Relationship

6
3

Authors

Journals

citations
Cited by 71 publications
(103 citation statements)
references
References 81 publications
3
97
1
2
Order By: Relevance
“…The GCV method tends to regularize less than the L-curve method ( figure 4(b)) and roughly produces a regularization level as was sometimes judiciously selected [11,24,27]. The full energy beam injection peak (60 keV) does not appear but there is a clear ridge of large phase-space densities between the expected locations of the beam injection peaks.…”
Section: Standard Inversions and The Choice Of The Regularization Parmentioning
confidence: 99%
“…The GCV method tends to regularize less than the L-curve method ( figure 4(b)) and roughly produces a regularization level as was sometimes judiciously selected [11,24,27]. The full energy beam injection peak (60 keV) does not appear but there is a clear ridge of large phase-space densities between the expected locations of the beam injection peaks.…”
Section: Standard Inversions and The Choice Of The Regularization Parmentioning
confidence: 99%
“…Good agreement is found for AUG#30382 at 2.5s where the remaining discrepancy can be explained by the absence of a source term (NBI fueling) in EBdyna. The FIDA diagnostic can further be used as a tomographic system ( [26], [27]) aimed at resolving the velocity space of fast Deuterium in the experiment [7]. The tomographic inversion of the FIDA measurements allows us to calculate the redistribution of fast particles resolved in velocity space.…”
Section: Fast Ions Deuterium-alpha (Fida) Spectroscopic Measurementsmentioning
confidence: 99%
“…For a more detailed analysis that includes all accessible wavelength ranges and viewing geometries, a tomographic inversion has been applied that is based on a truncated singular value decomposition as in previous work [34,35,36]. In this method the forward model to calculate FIDA spectra is formulated in the form of a matrix larger values for positive pitches than for negative pitches, explained by the co-current NBI injection geometry.…”
Section: Sawtooth-induced Fast-ion Transportmentioning
confidence: 99%