2004
DOI: 10.2116/bunsekikagaku.53.925
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of antioxidative activity against hypochlorite ion by sequential injection analysis with luminol chemiluminescence detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0

Year Published

2005
2005
2017
2017

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 13 publications
0
10
0
Order By: Relevance
“…Subsequently, a dose-response curve for each test compound was drawn by plotting the fluorescence peak height at each concentration of test compound against the concentration of the test compound (n = 5). The concentration of the test compound indicating 50% of the blank value was regarded as the EC 50 of the compound according to previous papers (23,24). Thus, in the present study, the EC 50 value (μM) was evaluated as the anti-oxidant activity of the test compound.…”
Section: Evaluation Of Anti-oxidant Activitymentioning
confidence: 99%
“…Subsequently, a dose-response curve for each test compound was drawn by plotting the fluorescence peak height at each concentration of test compound against the concentration of the test compound (n = 5). The concentration of the test compound indicating 50% of the blank value was regarded as the EC 50 of the compound according to previous papers (23,24). Thus, in the present study, the EC 50 value (μM) was evaluated as the anti-oxidant activity of the test compound.…”
Section: Evaluation Of Anti-oxidant Activitymentioning
confidence: 99%
“…[13][14][15] As mentioned above, ·OH is regarded as the most reactive species of ROS, and as such, ·OH scavenger should be effective to protect from serious oxidative stress caused by ·OH. Therefore, in this research, we developed the SIA-CL detection method to detect ·OH for the evaluation of ·OH scavenging activity.…”
Section: Introductionmentioning
confidence: 99%
“…In this method, the attenuation of luminol CL due to scavenging of ROS by sample was measured as the antioxidative activity. Successively, luminol CL detection was hyphenated with 7 sequential injection analysis (SIA) for determination of antioxidative activities against ClO -, 1 O 2 , O 2 -and NO [14][15][16]. Employing SIA makes it possible to reduce sample volume, reagent consumption and human error and obtain repeatable results, comparing with flow injection analysis [17].…”
Section: Introductionmentioning
confidence: 99%