Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device

Abstract: To measure precise blood pressure (BP) and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviatio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
23
0
2

Year Published

2013
2013
2020
2020

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 37 publications
(25 citation statements)
references
References 9 publications
0
23
0
2
Order By: Relevance
“…The periodicity of the pulse vessel has a special quality and relationship to the ECG wave and the BFV changes periodically [1,2]. The prototype products used in this research consisted of a permanent magnet, Hall sensor, measurement part, light emitting diode (LED), display panel, USB port, switch etc., as shown in Fig.…”
Section: Experimental Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The periodicity of the pulse vessel has a special quality and relationship to the ECG wave and the BFV changes periodically [1,2]. The prototype products used in this research consisted of a permanent magnet, Hall sensor, measurement part, light emitting diode (LED), display panel, USB port, switch etc., as shown in Fig.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…In general, blood flow velocity (BFV) monitored by measuring the signal of a pressurized sensor module in a patient's wrist or forearm does not provide customers with useful information regarding disease or health of the cardiovascular system [1]. Also, the BFV is difficult to measure by noninvasive methods under constant pressure without additional pressurization.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Used in this experiment, key component of clip-type pulsimeter and the displacement between the Hall effect device and the magnet is 2.5 mm [4,5]. The permanent magnet inside (1 mm), is moving up and down by high and low vibration, when placed at artery pulse.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…The oriental six pulses: the "Chon", "Chwan", and "Chuck" of both the left and right hand have to be carefully considered as they imply different meanings. Most of existing pulsimeters developed so far have a very critical limitation, they can only diagnose pulses from one spot [7,8].…”
Section: Introductionmentioning
confidence: 99%