1980
DOI: 10.1016/0161-5890(80)90163-7
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of bovine subclass antibodies (IgG1 and IgG2) using the amplified enzyme-linked immunosorbent assay

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

1981
1981
2009
2009

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 11 publications
0
4
0
Order By: Relevance
“…Treatment with Z nS04 alone failed to re move all Fc contamination. The specificity of the anti-y-chain rea gent was evaluated by immunodiffusion in the presence of poly ethylene glycol [30] and by the direct a-ELISA [27,28]. Guinea pig anti-y-chain was prepared and tested as described previously [13], IgG and IgA antibodies tc fluorescein and to OA were mea sured in the a-ELISA using F/-RSA and OA respectively.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Treatment with Z nS04 alone failed to re move all Fc contamination. The specificity of the anti-y-chain rea gent was evaluated by immunodiffusion in the presence of poly ethylene glycol [30] and by the direct a-ELISA [27,28]. Guinea pig anti-y-chain was prepared and tested as described previously [13], IgG and IgA antibodies tc fluorescein and to OA were mea sured in the a-ELISA using F/-RSA and OA respectively.…”
Section: Methodsmentioning
confidence: 99%
“…Guinea pig anti-y-chain was prepared and tested as described previously [13], IgG and IgA antibodies tc fluorescein and to OA were mea sured in the a-ELISA using F/-RSA and OA respectively. Quantita tion of antibodies in absolute units (/tg/ml) was performed using the 'direct' a-ELISA [27,28] in which known amounts of rabbit IgG or IgA are absorbed on plastic tubes to prepare a standard titration curve. The titration curve for IgG used in these studies showed loglog linearity from 0.38 to 7.5 ng.…”
Section: Methodsmentioning
confidence: 99%
“…OD41 of nonspecific binding was estimated by addition of PBS instead of test serum and corrected OD49' was obtained by subtracting that of nonspecific binding from each OD41. Data are expressed as means±SE of three or four determinations of ELISA units (corrected OD41 times primary serum dilution factor [=200]) as described elsewhere (18). Sera from PHN rats (PHN; n = 4) and PHN rats treated with daily oral MK886 administration (PHN + MK; n = 3) 10 d after the injection of anti-Fx IA antibody as described above were compared with those from normal control rats (Control; n = 4).…”
Section: Enzyme-linked Immunosorbent Assay For Anti-sheep Igg In Phn mentioning
confidence: 99%
“…ELISA for anti-sheep IgG in PHN rat sera was performed as previously described with slight modification (18). In brief, 100 jd of 200 time-diluted rat test sera was incubated in sheep IgG (Organon Teknika-Cappel, Malvern, PA)-coated 96-well microtiter plates (Becton Dickinson Labware, Lincoln Park, NJ) for 1 h at room temperature.…”
Section: Enzyme-linked Immunosorbent Assay For Anti-sheep Igg In Phn mentioning
confidence: 99%