2000
DOI: 10.1016/s0378-4347(00)00174-2
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of free and bound malondialdehyde in plasma by high-performance liquid chromatography as the 2,4-dinitrophenylhydrazine derivative

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
154
1
10

Year Published

2004
2004
2018
2018

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 219 publications
(170 citation statements)
references
References 34 publications
5
154
1
10
Order By: Relevance
“…We found mean 1.87±0.06 μmol/L of total MDA in human serum by using HPLC method as MDA-DNPH, This result is closed to the previous results reported by different authors with slight differences, these differences may be related to the factors such as age and nutrition of healthy volunteers [11].…”
Section: Resultscontrasting
confidence: 60%
See 2 more Smart Citations
“…We found mean 1.87±0.06 μmol/L of total MDA in human serum by using HPLC method as MDA-DNPH, This result is closed to the previous results reported by different authors with slight differences, these differences may be related to the factors such as age and nutrition of healthy volunteers [11].…”
Section: Resultscontrasting
confidence: 60%
“…The based determination of the MDA hydrazone, has proved to be precise and reproducible, as well as sensitive enough to reflect differences in the oxidative status in vivo [11]. In this method centrifugation of sample, followed by release of protein-bound MDA by alkaline hydrolysis of supernatants, and derivatization of MDA is required without any further extraction steps before direct injecting into the chromatographic system.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…16 MDA was measured by RP-HPLC and UV detection after derivatisation with 2,4-dinitrophenylhydrazine. 17 Total antioxidant capacity was measured by chemiluminescence detection in a BMG Fluostar Optima plate reader, using ABEL wide-range antioxidant kit from Knight Scientific Limited, UK. 18 Protein carbonyls were measured by an enzyme-linked immunosorbent assay (ELISA) method, with absorbance detection, using Zentech PC Kit from Zenith Technologies, New Zealand.…”
Section: Blood Analysesmentioning
confidence: 99%
“…A quantificação de MDA nos sistemas biológicos é um parâmetro importante para avaliação do estresse oxidativo celular (Pilz, Meineke, Gleiter, 2000;Sim et al, 2003). O método introduzido por Yagi (1976) tem sido amplamente utilizado.…”
Section: Introductionunclassified