Measurement of mean subcutaneous fat thickness: eight standardised ultrasound sites compared to 216 randomly selected sites

Abstract: Ultrasound (US) provides the most accurate technique for thickness measurements of subcutaneous adipose tissue (SAT) layers. This US method was recently standardised using eight sites to capture SAT patterning and allows distinguishing between fat and embedded fibrous structures. These eight sites chosen for fat patterning studies do not represent the mean SAT thickness measured all over the body that is necessary for determining subcutaneous fat mass. This was obtained by SAT measurements at 216 sites distrib… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
43
0
3

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 63 publications
(46 citation statements)
references
References 40 publications
(72 reference statements)
0
43
0
3
Order By: Relevance
“…Ultrasound images were evaluated interactively using an evaluation software (Rotosport, Austria; rotosport.at) for semiautomatic evaluations of SAT thicknesses. Sound speed was set to 1450 m s −1 for distance determination in fat [3,[18][19][20][21][22]. At each site, the software detects the SAT segments between the lower border of the skin and the upper border of the muscle fascia (for example, see Fig.…”
Section: Contour Detection and Sat Thickness Measurementsmentioning
confidence: 99%
See 2 more Smart Citations
“…Ultrasound images were evaluated interactively using an evaluation software (Rotosport, Austria; rotosport.at) for semiautomatic evaluations of SAT thicknesses. Sound speed was set to 1450 m s −1 for distance determination in fat [3,[18][19][20][21][22]. At each site, the software detects the SAT segments between the lower border of the skin and the upper border of the muscle fascia (for example, see Fig.…”
Section: Contour Detection and Sat Thickness Measurementsmentioning
confidence: 99%
“…Diagnostic (brightness-mode) ultrasound has been used for fat measurement since 1965 [33,34], and many publications followed. At sufficiently high probe frequency (12)(13)(14)(15)(16)(17)(18), the thickness measurement accuracy is approximately 0.1-0.2 mm [3,6,35], provided that the appropriate speed of sound in the given tissue is used (1450 ms −1 in fat [18][19][20][21][22]). The high accuracy enables measuring the embedded fibrous structures, which amount to substantial percentages of the SAT (Fig.…”
Section: Ultrasound Brightness-mode Imaging and Distance Measurement mentioning
confidence: 99%
See 1 more Smart Citation
“…As future studies, it is very important to properly evaluate the neck fat layer of the patient before any consideration of the feasibility of using Infrared Thermography exams for TN investigation. For instance, this can be done by US thickness measurements of subcutaneous adipose tissue layer in the same US exam used to nodule size evaluation 26 . Mathematical model.…”
Section: Discussionmentioning
confidence: 99%
“…Подібно до тварин з аліментарним ожирінням у котів і собак у разі цукрового діабету з симптомом ожиріння реєстрували значний вміст жирової тканини, що могло змінювати якість ультрасонографічної картини. Внаслідок поглинання ультразвуку жировою тканиною жирові прошарки можуть впливати на розміри внутрішніх органів, що погіршує оцінку стану їх паренхіми [14]. Підшкірний жировий прошарок візуалізується як нерухома субстанція під час дихання тварини, на відміну від абдомінального жиру та інших органів черевної порожнини [15].…”
Section: результати досліджень та їх обговоренняunclassified