1987
DOI: 10.2172/5327365
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of neutron spectra in varied environments by the foil-activation method with arbitrary trials

Abstract: Neutron spectra have been measured by the foil-activation method in 13 different environments in and around the Sandia Pulsed Reactor, the White Sands Missile Range Fast Burst Reactor, and the Sandia Annular Core Research Reactor. The spectra were obtained by using the SAND11 code in a manner that was not dependent on the initial trial. This altered technique is better suited for the determination of spectra in environments that are difficult to predict by calculation, and it tends to reveal features that may … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

1992
1992
2021
2021

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…Spectrum adjustment at Sandia National Laboratories is done primarily with an enhanced version of the SAND-II methodology [11,26]. When the new cross section library was assembled for the reactions in use at the Sandia RML, 15 previously determined spectra [27] were re-analyzed. Integral parameters, such as the spectral index (SI) and hardness parameter (HP) (defined by Kelly [27]), were not significantly altered by the updated cross sections.…”
Section: Fission Spectrum Determinationmentioning
confidence: 99%
See 1 more Smart Citation
“…Spectrum adjustment at Sandia National Laboratories is done primarily with an enhanced version of the SAND-II methodology [11,26]. When the new cross section library was assembled for the reactions in use at the Sandia RML, 15 previously determined spectra [27] were re-analyzed. Integral parameters, such as the spectral index (SI) and hardness parameter (HP) (defined by Kelly [27]), were not significantly altered by the updated cross sections.…”
Section: Fission Spectrum Determinationmentioning
confidence: 99%
“…When the new cross section library was assembled for the reactions in use at the Sandia RML, 15 previously determined spectra [27] were re-analyzed. Integral parameters, such as the spectral index (SI) and hardness parameter (HP) (defined by Kelly [27]), were not significantly altered by the updated cross sections. The quality of the fits, in term.,, of smoothness and standard deviation of experimental versus calculated activity, was slightly worse for the updated cross sections, but acceptable.…”
Section: Fission Spectrum Determinationmentioning
confidence: 99%
“…This conversion represents the atomic weight of isotopic 58Ni, 57.93534635 gm/mole (a mass excess of A = -60225 keV = 0.064653645 amu), divided by Avogadro's number, 6.0221367 x 1023 atoms/mole.…”
Section: Ni(np)s8codosimetry Reporting Methodologymentioning
confidence: 99%
“…The ASTM E-722 Standard has adopted a new definition for the hardness parameter HP [6] which has zero rather than 10 keV for the low energy integral limit. This means that the 1-MeV(Si) fluence is no longer equal to the product of the spectral shape parameter, SP, the hardness parameter, HP, and the fluence greater than 3-MeV, O3MeV' Note that the hardness parameter also depends upon the silicon displacement damage function that is used.…”
mentioning
confidence: 99%