Measurement of Plasma Free Cortisol, Estradiol, Testosterone and Prednisolone by Direct Radioimmunoassay of Ultrafiltrate and Its Clinical Application

Abstract: The authors aimed at developing a simplified method for the measurement of plasma free (unbound) steroids with ultrafiltration using Grace MPS device, and its clinical application. In this method, the movement of free steroids from plasma into ultrafiltrate was monitored with [14C]glucose added to the plasma. Plasma free steroids (cortisol, testosterone, estradiol and prednisolone) were measured as follows: Plasma was incubated with [14C]glucose (1.2 X 10(4) dpm/5 microliters) for 30 min at 37 degrees C. A 0.5… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2010
2010
2010
2010

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Dialysis involves an equilibration step of approximately 6-18 h 7,20 while ultrafiltration requires 30 -60 min equilibration and a 10-30 min centrifugation step. 18,19 Centrifree w ultrafiltration devices (Millipore, Bedford, MA, USA) have been employed for separating corticosteroids; 16,17,21,22 however, the small diameter of the sample reservoir makes the device difficult to load and therefore it is not amenable to automation. Microcon w centrifugal filter devices (Millipore, Bedford, MA, USA) are similar separation devices which can hold up to 0.5 mL of a biological specimen such as plasma.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Dialysis involves an equilibration step of approximately 6-18 h 7,20 while ultrafiltration requires 30 -60 min equilibration and a 10-30 min centrifugation step. 18,19 Centrifree w ultrafiltration devices (Millipore, Bedford, MA, USA) have been employed for separating corticosteroids; 16,17,21,22 however, the small diameter of the sample reservoir makes the device difficult to load and therefore it is not amenable to automation. Microcon w centrifugal filter devices (Millipore, Bedford, MA, USA) are similar separation devices which can hold up to 0.5 mL of a biological specimen such as plasma.…”
Section: Introductionmentioning
confidence: 99%
“…Samples can be easily loaded onto Microcon w centrifugal filter devices using automated liquid handlers and they have been used previously for isolating the free fraction of corticosteroids from plasma. 23 Previously published methods using liquid -liquid extraction, 22,24 protein precipitation, 23 radioimmunoassay 19 and detection by high-performance liquid chromatography (HPLC)-ultraviolet (UV) 22 or gas chromatography -MS 12 have high limits of quantification and involve laborious extraction and derivatization steps. On-line extraction methods for measuring cortisol in serum have been previously reported, but either no separation between cortisol and prednisolone was achieved with cortisol eluting at 28 min, 15 or a protein precipitation step preceded the on-line extraction.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation