2013
DOI: 10.1007/s10517-013-2095-3
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of Plasma Hemoglobin Peroxidase Activity

Abstract: We described a spectrophotometric method for measuring hemoglobin peroxidase activity in human plasma using o-dianisidine (o-DA) as the substrate and myeloperoxidase specific inhibitor 4-aminobensoic acid hydrazide (ruling out the probable contribution of myeloperoxidase to the measured parameter value). The optimal conditions (pH 5.5; 2 mM H2O2) have been determined, at which hemoglobin makes the main contribution to plasma oxidation of o-DA. A significant positive correlation between hemoglobin peroxidase ac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

4
5
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 26 publications
(9 citation statements)
references
References 3 publications
4
5
0
Order By: Relevance
“…Fig. 5 shows that significant differences were observed for the measured currents in the presence of Hb and HSA, similarly to that reported with other electrochemical immunosensors [28,68,69]. While Hb interference can be attributed to its well-documented endogenous peroxidase behavior [68], to our knowledge, the interference of HSA, although described in the literature [69], has not been explained.…”
Section: Selectivitysupporting
confidence: 82%
See 1 more Smart Citation
“…Fig. 5 shows that significant differences were observed for the measured currents in the presence of Hb and HSA, similarly to that reported with other electrochemical immunosensors [28,68,69]. While Hb interference can be attributed to its well-documented endogenous peroxidase behavior [68], to our knowledge, the interference of HSA, although described in the literature [69], has not been explained.…”
Section: Selectivitysupporting
confidence: 82%
“…5 shows that significant differences were observed for the measured currents in the presence of Hb and HSA, similarly to that reported with other electrochemical immunosensors [28,68,69]. While Hb interference can be attributed to its well-documented endogenous peroxidase behavior [68], to our knowledge, the interference of HSA, although described in the literature [69], has not been explained. Since our results show that the presence of HSA provoked an increase both in the specific and non-specific responses, we can hypothesize that HSA favors the possible non-specific adsorptions of the detection (TDP- or the secondary (HRP-anti-IgG) antibodies that occur in the absence of antigen.…”
Section: Selectivitysupporting
confidence: 80%
“…In the current study, the inherent PO activity of Hb was utilized to identify and display the presence and distribution of both cellular and non-cellular retained Hb. The PO activity of Hb has previously mainly been utilized in plasma for qualitative or quantitative measurement of Hb (Grigorieva et al, 2013 ), however protocol for the use in histochemistry has been described (Strum and Karnovsky, 1970 ). The use of PO activity in tissue as an adjunct to specific Hb immunolabeling, which showed excellent co-distribution, for sensitive recognition of intracellular and extracellular Hb proved invaluable in the current study for achieving a spatial overview of the Hb distribution.…”
Section: Discussionmentioning
confidence: 99%
“…Regardless of the S/B ratio, the amperometric signals for Gal-3 were slightly higher when HSA, hemoglobin, Lp(a) and sAXL (bars 2, 3, 6 and 7, respectively) were present in the solution, thus indicating a sort of small interference from these non-target proteins. Moreover, in the presence of hemoglobin a slightly higher signal was obtained (Figure 4, white bars 3) likely due to its intrinsic peroxidase activity [44,45]. It is worth mentioning also that the supplier of the used immunoreagents for immunosensor development claimed no potential cross-reactivity or interference towards substances with similar molecular structures such as recombinant human Gal-1, Gal-2, Gal-4 Gal-7, Gal-8 and Gal-10 (all assayed at 50 ng mL À 1 ).…”
Section: Selectivitymentioning
confidence: 97%