2017
DOI: 10.1016/j.nima.2017.04.037
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of radon concentration in super-Kamiokande’s buffer gas

Abstract: To precisely measure radon concentrations in purified air supplied to the Super-Kamiokande detector as a buffer gas, we have developed a highly sensitive radon detector with an intrinsic background as low as 0.33 ± 0.07 mBq/m 3 . In this article, we discuss the construction and calibration of this detector as well as results of its application to the measurement and monitoring of the buffer gas layer above Super-Kamiokande. In March 2013, the chilled activated charcoal system used to remove radon in the input … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
27
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 30 publications
(30 citation statements)
references
References 36 publications
3
27
0
Order By: Relevance
“…In addition, in order to reduce the intrinsic background, the inner surface of the stainless vessel has been electropolished. Because of these improvements, the intrinsic background becomes 0.33 ± 0.07 mBq/m 3 , which is lower than that of the previous 70 litter Rn detectors by a factor of three [13,10]. Finally, this low-background detector enables to measure ∼0.5 mBq/m 3 level of Rn concentration for a single day measurement.…”
Section: High-sensitivity Rn Detector and Its Applicationmentioning
confidence: 92%
See 3 more Smart Citations
“…In addition, in order to reduce the intrinsic background, the inner surface of the stainless vessel has been electropolished. Because of these improvements, the intrinsic background becomes 0.33 ± 0.07 mBq/m 3 , which is lower than that of the previous 70 litter Rn detectors by a factor of three [13,10]. Finally, this low-background detector enables to measure ∼0.5 mBq/m 3 level of Rn concentration for a single day measurement.…”
Section: High-sensitivity Rn Detector and Its Applicationmentioning
confidence: 92%
“…We have developed an 80-litter high sensitivity Rn detector to measure Rn concentrations in either the air [13] or the novel gases [12]. Figure 3 shows the design of the 80-litter Rn detector and its energy spectrum of the background measurement [13].…”
Section: High-sensitivity Rn Detector and Its Applicationmentioning
confidence: 99%
See 2 more Smart Citations
“…According to the MC simulation for JUNO experiment requirements, the Rn concentration in the water should be less than 0.2 Bq/m 3 [1]. The high-sensitivity Rn assay is one of the essential techniques for JUNO as well as other underground experiments [2,3].…”
Section: Introductionmentioning