1999
DOI: 10.1177/000456329903600302
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of Selenium in Clinical Specimens

Abstract: Additional key phrases: molecular fluorescence spectrometry; hydride; generation atomic absorption lind atomic fluorescence spectrometry; graphite furnace atomic absorption spectrometry; inductively-coupled plasma mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0
4

Year Published

2000
2000
2009
2009

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(25 citation statements)
references
References 85 publications
0
21
0
4
Order By: Relevance
“…Blood selenium concentration is generally considered a useful measure of both selenium status and intake, but other tissues such as hair and nails are also used (Nève, 1991;Burk & Levander, 1999;Sheehan & Halls, 1999). Plasma or serum selenium reflects short-term status, and erythrocyte selenium reflects longer-term status, due to the incorporation of selenium during synthesis of these cells.…”
Section: Biochemical Tests For Nutritional Status Of Seleniummentioning
confidence: 99%
“…Blood selenium concentration is generally considered a useful measure of both selenium status and intake, but other tissues such as hair and nails are also used (Nève, 1991;Burk & Levander, 1999;Sheehan & Halls, 1999). Plasma or serum selenium reflects short-term status, and erythrocyte selenium reflects longer-term status, due to the incorporation of selenium during synthesis of these cells.…”
Section: Biochemical Tests For Nutritional Status Of Seleniummentioning
confidence: 99%
“…Serum Selenium levels were determined by graphite furnace atomic absorption spectroscopy (GFAAS) (Perkin Elmer Atomic Absorption Spectrophotometer A Analyst 800), using an Electrodeless Discharge Lamp (EDL) at 196.0 nm, with transversal heated furnace atomizer (THGA) and Zeeman effect background correction as described elsewhere (Sheehan and Halls, 1999). The interassay variation was 3.1%.…”
Section: Analytical Proceduresmentioning
confidence: 99%
“…From the data presented in Table 3, it became evident that some proteins, such as those corresponding to Spots 10,13,15,16,19 and 20, were more abundant when diets were supplemented with SeMSeCys. Since Spots 10,11,13,14,15,17,18,19 and 20 were not detected in the control conditions, P values could not be calculated, although we considered that these proteins were overexpressed in response to SeMSeCys supplementation.…”
Section: Resultsmentioning
confidence: 99%
“…Alternative measurements of selenium bioavailability that are based on the assessment of the activity of other selenoproteins have been proposed [16,17]. However, their use as selenium biomarkers has not been demonstrated quite likely because of analytical requirements and low reproducibility.…”
Section: Nutritional Biomarkers and Selenium Intakementioning
confidence: 99%