2018
DOI: 10.1016/j.nima.2018.03.055
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of the absolute neutron beam polarization from a supermirror polarizer and the absolute efficiency of a neutron spin rotator for the NPDGamma experiment using a polarized  3He neutron spin-filter

Abstract: Accurately measuring the neutron beam polarization of a high flux, large area neutron beam is necessary for many neutron physics experiments. The Fundamental Neutron Physics Beamline (FnPB) at the Spallation Neutron Source (SNS) is a pulsed neutron beam that was polarized with a supermirror polarizer for the NPDGamma experiment. The polarized neutron beam had a flux of ∼ 10 9 neutrons per second per cm 2 and a cross sectional area of 10×12 cm 2 . The polarization of this neutron beam and the efficiency of a RF… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
7
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
5
1

Relationship

4
2

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 20 publications
1
7
0
Order By: Relevance
“…where A PC and A PV are the parity-conserving and parity-violating physics asymmetries, A i app is a term encompassing contributions that dilute the asymmetry, P n is the measured neutron beam polarization [7], ∆ dep is the neutron depolarization correction, and ∆ sf is the spin flip efficiency. Using the super ratio method is superior to using the difference between detector signals because it perfectly accounts for the differences in the gains of the detectors in each pair and is less sensitive to differential detector pedestal values.…”
Section: Lhmentioning
confidence: 99%
“…where A PC and A PV are the parity-conserving and parity-violating physics asymmetries, A i app is a term encompassing contributions that dilute the asymmetry, P n is the measured neutron beam polarization [7], ∆ dep is the neutron depolarization correction, and ∆ sf is the spin flip efficiency. Using the super ratio method is superior to using the difference between detector signals because it perfectly accounts for the differences in the gains of the detectors in each pair and is less sensitive to differential detector pedestal values.…”
Section: Lhmentioning
confidence: 99%
“…The experiment performed in June used two 3 He spin filter cells of different length; Olaf (N He L = 5.5 bar-cm) and Syrah (N He L = 13.3 bar-cm). [17] The small variation in GE180 glass transmission with wavelength was neglected [8,18] and T e = 0.88 was assumed for both cells. [10] Two cells were used as opposed to only one because we believed this would allow us to observe any effect due to a polychromatic neutron wavelength spectrum.…”
Section: Resultsmentioning
confidence: 99%
“…Such spin filters have also been used for polarization analysis on a range of neutron-based instruments such as triple-axis spectrometers, small-angle neutron scattering instruments, and reflectometers. [5] Spin filters have been used for highly accurate neutron beam polarization measurements on polarized neutron beams, [6,7,8,9,10] but aCORN is in a class of experiments that is sensitive to a slight polarization on a nominally unpolarized beam. [1,11,12] Polarized 3 He has a large absorption cross section for neutrons of antiparallel spin and a negligible cross section for neutrons of parallel spin.…”
Section: Introductionmentioning
confidence: 99%
“…and which should be compared to equation 15 below. The spin flip terms for a neutron with spin along theẑ factor in equation 10. The probability that any given particle interaction leads to a spin flip is given by…”
Section: Spin-flip Scattering Formalismmentioning
confidence: 99%
“…The neutrons are incident on the 16-liter liquid hydrogen target [8] that is surrounded by 48 CsI(Tl) detectors arranged in 4 rings of 12 detectors each [9] that detect the γ-rays from neutron capture. The average neutron beam polarization is measured with an empty liquid hydrogen target vessel, and a 3 He spin filter [10] followed by a 3 He transmission monitor [11] downstream of the vessel are used to measure the beam polarization. A uniform 9.5 gauss magnetic field aligned within 3 mrad to the vertical axis (ẑ) transports polarized neutrons to the target vessel [1].…”
Section: Introductionmentioning
confidence: 99%