2008
DOI: 10.1016/j.flowmeasinst.2008.05.005
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of the fluid flow rate with use of an elbow with oval cross section

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
7
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 1 publication
0
7
0
Order By: Relevance
“…This sensor is claimed to have very good immunity to external vibration and is recommended for industrial applications where an extremely small volume of liquid is required to be mixed. Malinowski and Rup [12] have utilised the pressure across an elbow of a pipe line as a flow measuring parameter. They have shown that the measurement uncertainties due to pipe vibration may be minimised by using large-diameter pipe at the large flow and small curvature of the elbow at low flow.The effect of centrifugal force produced by the flowing fluid through the lower semicircular section of a vertically mounted U-tube is utilised by Bera [13] to develop a low-cost non-contact flow transducer.…”
Section: Introductionmentioning
confidence: 99%
“…This sensor is claimed to have very good immunity to external vibration and is recommended for industrial applications where an extremely small volume of liquid is required to be mixed. Malinowski and Rup [12] have utilised the pressure across an elbow of a pipe line as a flow measuring parameter. They have shown that the measurement uncertainties due to pipe vibration may be minimised by using large-diameter pipe at the large flow and small curvature of the elbow at low flow.The effect of centrifugal force produced by the flowing fluid through the lower semicircular section of a vertically mounted U-tube is utilised by Bera [13] to develop a low-cost non-contact flow transducer.…”
Section: Introductionmentioning
confidence: 99%
“…When a classical measuring orifice is used to measure the flow rate, it is necessary to install long pipeline sections with a circular cross section (Bean, 1971; PN-EN ISO 5167-1, 2004; Spitzer, 2001). It appears that circular-shaped elbow flow meters, which have been installed on the pipeline, enable to obtain a signal that corresponds to the entire volumetric rate of the fluid flow (Malinowski and Rup, 2008; Spitzer, 2001). The principle that pertains to operation of elbow flow meter is based on the use of the ratio of volumetric rate of flow to the difference between pressures measured at extreme points of elbow arc secant.…”
Section: Introductionmentioning
confidence: 99%
“…In practice, engineers sometimes use a solution where the pressure is measured through pulse apertures that are situated along the plane, which is not aligned with the secant. In such a case, the measured pressure difference attains lower values (Malinowski and Rup, 2008; Spitzer, 2001). The standard measurement is carried out in the following manner: a pressure difference is measured, and subsequently, a relevant volumetric flow rate value is assigned based on the previously worked out characteristics of the instrument.…”
Section: Introductionmentioning
confidence: 99%
“…Then the hot helium releases its thermal power to the water in the secondary loop and is cooled down to around 250 ∘ C. The cooled helium from 14 riser pipes collects into the header box and is pumped back to the reactor by the blower. Each of the riser pipes is connected to the header box by a 90 ∘ elbow, as shown in Figure 1(b), which is used as the sensor to measure the helium flow rate by monitoring the pressure difference between its intrados and extrados [7][8][9].…”
Section: Introductionmentioning
confidence: 99%