2020
DOI: 10.1016/j.nima.2019.163381
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of the relative response of small-electrode CMOS sensors at Diamond Light Source

Abstract: This paper outlines the results of investigations into the effects of radiation damage in the mini-MALTA prototype. Measurements were carried out at Diamond Light Source using a micro-focus X-ray beam, which scanned across the surface of the device in 2 µm steps. This allowed the in-pixel photon response to be measured directly with high statistics. Three pixel design variations were considered: one with the standard continuous n − layer layout and front-end, and extra deep p-well and n − gap designs with a mo… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
2
2
2

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 10 publications
0
10
0
Order By: Relevance
“…Coupled with the results from Diamond described in [12], the X-ray irradiations show that MiniMALTA is fully operational after TID above the ALTAS requirement, and efficiencies are expected to be comparable to those of devices without TID.…”
Section: X-ray Irradiationsmentioning
confidence: 61%
See 2 more Smart Citations
“…Coupled with the results from Diamond described in [12], the X-ray irradiations show that MiniMALTA is fully operational after TID above the ALTAS requirement, and efficiencies are expected to be comparable to those of devices without TID.…”
Section: X-ray Irradiationsmentioning
confidence: 61%
“…There are actually more hits between pixels than in the pixel centers for this sector. The sector with the n-gap substrate and modified front-end had comparable performance, and in both designs the charge collection in the periphery after irradiation has improved with the new substrate and front-end designs [12].…”
Section: Pos(vertex2019)020mentioning
confidence: 94%
See 1 more Smart Citation
“…In these proceedings, I compare results from two sectors in a neutron irradiated (1e15 n eq /cm 2 ) MiniMALTA sample. A more thorough analysis of the test beam is in [12].…”
Section: Diamond Setupmentioning
confidence: 99%
“…Most recently, the mini-MALTA prototype was developed, implementing design changes which are aimed at improving the pixel performance and achieving higher radiation hardness [3]. In the following, results of an X-Ray test-beam at Diamond Light Source are presented for the different designs and different levels of irradiation [4].…”
Section: Introductionmentioning
confidence: 99%