2014
DOI: 10.1364/boe.5.000630
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of the total retinal blood flow using dual beam Fourier-domain Doppler optical coherence tomography with orthogonal detection planes

Abstract: Abstract:We present a system capable of measuring the total retinal blood flow using a combination of dual beam Fourier-domain Doppler optical coherence tomography with orthogonal detection planes and a fundus camera-based retinal vessel analyzer. Our results show a high degree of conformity of venous and arterial flows, which corroborates the validity of the measurements. In accordance with Murray's law, the log-log regression coefficient between vessel diameter and blood flow was found to be ~3. The blood's … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

6
100
0
2

Year Published

2014
2014
2020
2020

Publication Types

Select...
7
2

Relationship

3
6

Authors

Journals

citations
Cited by 87 publications
(110 citation statements)
references
References 37 publications
6
100
0
2
Order By: Relevance
“…In humans, several techniques were realized to quantify retinal perfusion. 7,16,18,20,25,[31][32][33][34][35][36] In rats, a technique was proposed to measure the axial blood velocity in an en-face plane using raster scanning in a very small area around the central retinal artery. The retinal blood flow was calculated by integrating over the vessel area.…”
Section: Discussionmentioning
confidence: 99%
“…In humans, several techniques were realized to quantify retinal perfusion. 7,16,18,20,25,[31][32][33][34][35][36] In rats, a technique was proposed to measure the axial blood velocity in an en-face plane using raster scanning in a very small area around the central retinal artery. The retinal blood flow was calculated by integrating over the vessel area.…”
Section: Discussionmentioning
confidence: 99%
“…Experimental diabetes in rats was induced by a single subcutaneous injection of alloxan with a dose of 220 mg/kg body weight of the animal. Alloxan disturbed pancreas functioning leading to development of diabetes in rats [6]. Status of diabetes was confirmed by the increase of glucose level in the blood that was tested by using a commercial glucometer Accu-Chek Active (Roche Diagnostics, Germany).…”
Section: Animal Modelsmentioning
confidence: 99%
“…Currently, the most effective diagnostic methods for determining the physiological parameters of blood flow and microcirculation are the methods based on dynamic light scattering [5], as well as on principles of lowcoherence optical coherence tomography (OCT), the so called Doppler OCT (DOCT) [6][7][8]. One of the prospective methods for the assessment of blood flow is the Laser Speckle Contrast Imaging (LSCI) [9][10][11][12][13][14][15].…”
Section: Introductionmentioning
confidence: 99%
“…12,13 The studies were undertaken to measure total retinal blood flow and total retinal oxygen extraction in healthy subjects. The study protocols were approved by the Ethics Committee of the Medical University of Vienna and followed the guidelines set forth in the Declaration of Helsinki.…”
Section: Subjectsmentioning
confidence: 99%