Measurement of the volume growth rate of single budding yeast with the MOSFET-based microfluidic Coulter counter

Abstract: We report on measurements of the volume growth rate of ten individual budding yeast cells using a recently developed MOSFET-based microfluidic Coulter counter. The MOSFET-based microfluidic Coulter counter is very sensitive, provides signals that are immune from the baseline drift, and can work with cell culture media of complex composition. These desirable features allow us to directly measure the volume growth rate of single cells of Saccharomyces cerevisiae LYH3865 strain budding yeast in YNB culture media … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

1
43
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 33 publications
(44 citation statements)
references
References 42 publications
1
43
0
Order By: Relevance
“…Microfluidic channels are fabricated using standard soft-lithography techniques with an SU8 master mold on a silicon substrate. 4 The microfluidic chip for leakage tests has a straight channel which is 50 μm wide (or 300 μm wide), 50 μm deep, and 6 cm long (Fig. 1a).…”
mentioning
confidence: 99%
“…Microfluidic channels are fabricated using standard soft-lithography techniques with an SU8 master mold on a silicon substrate. 4 The microfluidic chip for leakage tests has a straight channel which is 50 μm wide (or 300 μm wide), 50 μm deep, and 6 cm long (Fig. 1a).…”
mentioning
confidence: 99%
“…Events shown in B and C are for particles suspended in a 21% glycerol solution, making them practically neutrally buoyant. The 21% glycerol solution has a density of 1.065 g/cm 3 , which only slightly differs from that of the microspheres (1.062 g/cm 3 ). This small difference in densities is sufficient to cause a slight settling along the vertical axis in the timeframe of the experiment.…”
mentioning
confidence: 99%
“…Each buffer contained 0.1% bovine serum albumin (BSA), 0.1 M KCl, and varying concentrations of glycerol (0%, 21%, or 42%). Carrier fluid densities were quantified with a suspended microchannel resonator (SMR): 10 1.004 6 0.001 g/cm 3 , 1.065 6 0.001 g/cm 3 , and 1.121 6 0.001 g/cm 3 for 0%, 21%, and 42% glycerol solutions, respectively. To prevent beads from non-specifically interacting with microchannel surfaces, 0.1% g/ml of detergent (Contrex, Decon Labs Inc.) was added prior to experimentation to both the water and glycerol heavy solutions.…”
mentioning
confidence: 99%
“…Time-lapse fluorescence microscopy can provide valuable information as to the cell cycle progression of individual cells, 5 but 2D optics requires geometric assumptions, and, thus, can provide an incomplete picture of growth. 6,7 Microfluidic lab-on-chip devices with integrated sensors can provide high-resolution growth tracking of individual cells, either through mass, volume, or density monitoring. 4,7,8 Recently, a microfluidic mass sensor was used to track the buoyant mass of individual cells using a suspended microchannel resonator (SMR).…”
mentioning
confidence: 99%
“…6,7 Microfluidic lab-on-chip devices with integrated sensors can provide high-resolution growth tracking of individual cells, either through mass, volume, or density monitoring. 4,7,8 Recently, a microfluidic mass sensor was used to track the buoyant mass of individual cells using a suspended microchannel resonator (SMR). 4,9 Monitoring growth can also be accomplished by tracking volume using microfluidic volume sensors 7 operating on the Coulter principle.…”
mentioning