Measurement of Thermal Effects of Doppler Ultrasound: An In Vitro Study

Abstract: ObjectiveUltrasound is considered a safe imaging modality and is routinely applied during early pregnancy. However, reservations are expressed concerning the application of Doppler ultrasound in early pregnancy due to energy emission of the ultrasound probe and its conversion to heat. The objective of this study was to evaluate the thermal effects of emitted Doppler ultrasound of different ultrasound machines and probes by means of temperature increase of in-vitro test-media.MethodsWe investigated the energy-o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
13
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(14 citation statements)
references
References 30 publications
0
13
0
1
Order By: Relevance
“…The long-term PUS biophysical effects 6,7 on the embryo/fetus featuring the acoustic output of new ultrasonic devices, 15,16,85 its overuse in clinical practice 10,77 and the commercial fetal video souvenirs 91-94 remain unknown.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The long-term PUS biophysical effects 6,7 on the embryo/fetus featuring the acoustic output of new ultrasonic devices, 15,16,85 its overuse in clinical practice 10,77 and the commercial fetal video souvenirs 91-94 remain unknown.…”
Section: Resultsmentioning
confidence: 99%
“…This advancement was followed, in the 1990s, by real-time processable threedimensional (3-D) and four-dimensional (4-D) arrays, which is 3-D visualization with motion. 15,16…”
Section: History Of Pusmentioning
confidence: 99%
“…This is why exposure time and ALARA are important in the first trimester, because an ultrasound operator may have a difficult time estimating where the highest temperature changes could be along the sound beam. 25 STIC is considered a form of 4D imaging, and it has been recommended to keep the TI less than 1.0. In addition, the scan time during real-time volume acquisition should be kept under 30 minutes.…”
Section: Discussionmentioning
confidence: 99%
“…Beim Farbdoppler sind die Werte etwas höher (0,62, 0,53 und 0,52), am höchsten sind sie beim gepulsten Doppler (1,65 im ersten Trimenon, 1,67 im zweiten Trimenon und 1,89 im dritten Trimenon), jedoch wurden hier Spitzenwerte von bis zu 3,0 erreicht. Die Amerikanische und Britische Ultraschallgesellschaft sowie die EFSUMB haben Empfehlungen herausgegeben, nach denen der TI am besten unter 0,7 liegen sollte [5][6][7][8][9]. Theoretisch könnte man dann zeitlich unbegrenzt Ultraschall durchführen, was natürlich in der Praxis nicht stattfindet (ALARA-Prinzip).…”
Section: Sicherheitsaspekte Des Ultraschalls In Der Pränataldiagnostikunclassified
“…They are highest in pulsed Doppler (1.65 in the first trimester, 1.67 in the second trimester, and 1.89 in the third trimester), with peak values of up to 3.0 being achieved. According to the recommendations published by the American Institute of Ultrasound in Medicine, the British Medical Ultrasound Society and the EFSUMB, the TI should ideally be less than 0.7 [5][6][7][8][9]. Theoretically, ultrasound could then be performed without time limits, which of course would not actually happen in practice (ALARA principle).…”
mentioning