2005
DOI: 10.1016/j.lab.2005.04.004
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of total and differential white blood cell counts in synovial fluid by means of an automated hematology analyzer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
23
0
5

Year Published

2007
2007
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 35 publications
(29 citation statements)
references
References 10 publications
1
23
0
5
Order By: Relevance
“…Studies on flow-cytometer cell counting in SF samples are of particular relevance to our results on the Luminex platform (Moreno et al, 2000;Sugiuchi et al, 2005;Ekmann et al, 2010). These studies demonstrate that HAse treatment improved the precision by reducing errors due to high viscosity related flow.…”
Section: Discussionsupporting
confidence: 53%
See 1 more Smart Citation
“…Studies on flow-cytometer cell counting in SF samples are of particular relevance to our results on the Luminex platform (Moreno et al, 2000;Sugiuchi et al, 2005;Ekmann et al, 2010). These studies demonstrate that HAse treatment improved the precision by reducing errors due to high viscosity related flow.…”
Section: Discussionsupporting
confidence: 53%
“…These properties can make the analysis of SF from OA joints challenging. Consequently, methods to reduce SF viscosity by dilution and/or hyaluronidase (HAse) treatment are routinely used before a variety of analytic techniques (Song et al, 2012;Mateos et al, 2012;Sugiuchi et al, 2005;de Jager et al, 2007;Ekmann et al, 2010).…”
Section: Introductionmentioning
confidence: 99%
“…Como a viscosidade do líquido sinovial está diretamente relacionada ao conteúdo de hialuronato (SUGIUCHI et al, 2005;TULAMO et al, 1994;TULAMO et al, 1996), a diminuição observada no 30 o po é sugestiva de trauma articular causado pela desmotomia patelar medial. Segundo SUGIUCHI et al (2005), na presença de inflamação, as enzimas no líquido sinovial quebram a molécula de hialuronato, o volume de líquido sinovial aumenta e a viscosidade diminuiu.…”
Section: Discussionunclassified
“…In the following hour, the specimen was analyzed by a second blinded observer in the same way. Every day, a new slide was prepared; native SF was pretreated with hyaluronidase to disintegrate clots (H3506 Type I-S from Bovine Tests, Fa; Sigma-Aldrich, St Louis, MO) as described by Sugiuchi et al 11 Daily crystal analysis was conducted blinded, which means that each fluid was examined by a different analyst each successive day and without the knowledge of earlier results. The results were documented independently and fixed in a protocol by an uninvolved third person (medical technician).…”
Section: Analysis Of Crystalsmentioning
confidence: 99%