2021
DOI: 10.1055/s-0041-1740236
|View full text |Cite
|
Sign up to set email alerts
|

Measurement Performance of Activity Measurements with Newer Generation of Apple Watch in Wheelchair Users with Spinal Cord Injury

Abstract: Background The level of physical activity (PA) of people with spinal cord injury (SCI) has an impact on long-term complications. Currently, PA is mostly assessed by interviews. Wearable activity trackers are promising tools to objectively measure PA under everyday conditions. The only off-the-shelf, wearable activity tracker with specific measures for wheelchair users is the Apple Watch. Objectives This study analyzes the measurement performance of Apple Watch Series 4 for wheelchair users and compar… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
19
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(19 citation statements)
references
References 24 publications
0
19
0
Order By: Relevance
“…Overall, compared to manual counting, SW slightly undercounted total pushes (SD) averaged across 16 workloads (manual: 50 [8] pushes vs SW: 48 [8] pushes). We suspect the SW undercounting could stem from discrepancies of defining a "push" or due to a push occurring on the wheel and not the push rim where the sensor on the SW is located.…”
Section: Discussionmentioning
confidence: 92%
See 3 more Smart Citations
“…Overall, compared to manual counting, SW slightly undercounted total pushes (SD) averaged across 16 workloads (manual: 50 [8] pushes vs SW: 48 [8] pushes). We suspect the SW undercounting could stem from discrepancies of defining a "push" or due to a push occurring on the wheel and not the push rim where the sensor on the SW is located.…”
Section: Discussionmentioning
confidence: 92%
“…Conversely, compared to manual counting, both ActiGraph accelerometers overcounted total pushes (SD) averaged across all 16 workloads (upper arm: 54 [11] pushes, wrist: 63 [12] pushes, manual: 50 [8] pushes). Due to limited research in using wearable devices for wheelchair push counts, comparisons of our study population with existing research are limited.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The Irish and Canadian teams reported a "lack of appropriate accelerometer data," which projects further challenges to collecting PA data accurately. It should be acknowledged in this regard that atypical gait as well as wheelchair use are still not accurately measured using off-the-shelf wearable smart devices (Benning et al, 2021). To fill this gap, the Canadian team challenged the policymakers to create "populationspecific guidelines" customized for CAWD (Arbour-Nicitopoulos et al, 2022).…”
Section: Internal Domains-strength and Weaknessesmentioning
confidence: 99%