2021
DOI: 10.3390/en14144353
|View full text |Cite
|
Sign up to set email alerts
|

Measurement Tests and FEM Calculations of DC Excited Flux Switching Motor Prototype

Abstract: The paper presents the results of laboratory tests and FEM 2D calculations of the DCEFSM (Direct Current Excited Flux Switching Machine) electric motor prototype, made based on the stator ferromagnetic sheets of the induction motor. Static measurements of torques, currents, power, efficiency, electromotive forces, and voltages of the motor under various operating conditions were performed, as well as the recordings of its currents and back-EMFs waveforms. FEM calculations of measured values were also performed… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(4 citation statements)
references
References 20 publications
0
4
0
Order By: Relevance
“…The rated motor speed of 1500 rpm was achieved with a supply voltage frequency of 375 Hz. The rated motor parameters (obtained from measurements [1]) are presented in Table 1. The rated values of both currents result from the admissible temperature of both windings during their operation (due to the thermal class of their insulation).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The rated motor speed of 1500 rpm was achieved with a supply voltage frequency of 375 Hz. The rated motor parameters (obtained from measurements [1]) are presented in Table 1. The rated values of both currents result from the admissible temperature of both windings during their operation (due to the thermal class of their insulation).…”
Section: Methodsmentioning
confidence: 99%
“…Compared to 10 A, it results in torque that is only about 5% lower (for a set armature current). The measurements, the results of which are presented in a previous paper [1], were made at the speed of 1200 rpm, instead of the rated speed of 1500 rpm, due to technical limitations on the test bench. Therefore, the calculations in this paper were also carried out at a speed of 1200 rpm, for the sake of consistency with the earlier paper [1].…”
Section: Methodsmentioning
confidence: 99%