2015
DOI: 10.1016/j.radphyschem.2014.09.009
|View full text |Cite
|
Sign up to set email alerts
|

Measurements of L shell X-ray yields of thick Ag target by 6–29keV electron impact

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 38 publications
0
7
0
Order By: Relevance
“…Bote et al (2008) showed that K and L X-ray yields calculated by using PENELOPE were in reasonably good agreement with experimental measurements taken from the literature. Li et al (2014) and Zhao et al (2015) carried out their own X-ray yield measurements and showed that their experimental data compared favorably, to within ~10%, with the predictions of PENELOPE. More recently, Moy et al (2015) performed new absolute X-ray yield measurements for several high- Z element materials, which were found to agree satisfactorily with the predictions of PENEPMA.…”
Section: Examples Of Applications Of Penepmamentioning
confidence: 96%
“…Bote et al (2008) showed that K and L X-ray yields calculated by using PENELOPE were in reasonably good agreement with experimental measurements taken from the literature. Li et al (2014) and Zhao et al (2015) carried out their own X-ray yield measurements and showed that their experimental data compared favorably, to within ~10%, with the predictions of PENELOPE. More recently, Moy et al (2015) performed new absolute X-ray yield measurements for several high- Z element materials, which were found to agree satisfactorily with the predictions of PENEPMA.…”
Section: Examples Of Applications Of Penepmamentioning
confidence: 96%
“…In this paper, the experimental setup is similar to that of Li et al [41] and Zhao et al [42]. In order to obtain more accurate experimental data, the deep Faraday cup was redesigned and its schematic drawing is shown in figure 1.…”
Section: Methodsmentioning
confidence: 99%
“…In analogy to the data processing method for the electron impact described in ref. [30], the Ag L αβγ X-ray production cross-sections impacted by the positron are obtained by multiplying its own data in the database of the PENELOPE-2005 by the scaling factor 1.08 (Ag L αβγ X-ray production cross-sections based on the database of PENELOPE-2005 can be calculated by the Ag L i subshell ionization cross-sections and atomic relaxation parameters taken from the database of PENELOPE-2005 according to eqs. ( 3) and (4) in ref.…”
Section: Experimental Technique -mentioning