2015
DOI: 10.1103/physrevc.92.014624
|View full text |Cite
|
Sign up to set email alerts
|

Measurements of theKr86(n,γ)Kr87

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

2
2
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 19 publications
2
2
0
Order By: Relevance
“…The input parameters have been varied in accordance with the statistical and systematic uncertainties to produce the red-hashed error-band. We observe an overall good agreement with direct measurements by Bhike et al [58] and a decent agreement at higher energies with measurements of Walter et al [59], while somewhat high compared 1 Version 1.9. Fig.…”
Section: Neutron Capture Cross Sectionssupporting
confidence: 90%
See 1 more Smart Citation
“…The input parameters have been varied in accordance with the statistical and systematic uncertainties to produce the red-hashed error-band. We observe an overall good agreement with direct measurements by Bhike et al [58] and a decent agreement at higher energies with measurements of Walter et al [59], while somewhat high compared 1 Version 1.9. Fig.…”
Section: Neutron Capture Cross Sectionssupporting
confidence: 90%
“…The gray and blue lines are from the evaluation of ENDF/B-VII.1 [8] and the TALYS default input, respectively, and is provided for comparison. The black triangles shows the direct measurements of Bhike et al [58], the blue upside-down triangles are results from time-of-flight measurements of Walter et al [59] and the turquoise circles are the results from the activation measurements of Beer et al [60] with the activation results of Beer et al [60]. The Maxwellian average (MACS) at the typical s-process temperature of 30 keV is found to be 7.2(36) mb, which is higher than the evaluated value of 3.4(3) mb found in KaDoNis [61].…”
Section: Neutron Capture Cross Sectionsmentioning
confidence: 99%
“…The input parameters have been varied in accordance with the statistical and systematic uncertainties to produce the red hashed error-band. We observe an overall good agreement with the direct measurements of Walter et al [52] and Bhike et al [53], while somewhat high compared with the activation results of Beer et al [54].…”
Section: Neutron Capture Cross Sectionssupporting
confidence: 90%
“…The yellow and blue lines are from the evaluation of ENDF/B-VII.1[7] and the TALYS default input, respectively, and is provided for comparison. The black triangles shows the direct measurements of Bhike et al[53], the blue upside-down triangles are results from time-of-flight measurements of Walter et al[52] and the turquoise circles are the results from the activation measurements of Beer et al[54].…”
mentioning
confidence: 99%