Thermodynamic properties of refrigerants are of great iniportance in the design and simulation of heat pumps and refrigeration units. The parameter values in the modified Benedict-Webb-Rubin equation of state proposed by Lee and Kesler (1975) have been determined for HFC134a with the Error-in-Variables Model. The types of data used for the parameter estimation have been: pressure-volume-temperature data for subcooled and superheated conditions, vapour pressures, saturated vapour and liquid volumes, isobaric arid isochoric heat capacities and second virial coefficients. Calculations carried out with the equation of state according to Lee and Kesler, with the parameters here proposed, agree well with experimental data for the fluid. Les proprittks thermodynamiques des rtfrigtrants sont d'une grande importance dans la conception et la simulation des pompes h chaleur et ties systbmes de rtfrigtration. Les valeurs des parmktres dans l'kquation d'ttat Benedict-Webb-Rubin modifik propode par Lee et Kesler (1975), ont ttk d6termides pour HFC134a avec le modble des erreurs dam les variables. Les dondes u t i l i k pour I'estimation des parami?tn=s sont les suivantes: pression-volume-temp6rature pour des conditions de sous-refroidissement et de surchaufibment, pression de vapeur, volumes de vapeur satu& et de liquide, capacitks thermiques isobares et isochores, enfin!, le deuxibme coefficient des viriels. Les calculs effectuts avec I'kquation d'ttat de Lee et Kesler, avec les paramktres propods ici, concordent bien avec les donnks exphimentales obtenues pour le fluide.